My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_JUN 2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
930
>
2300 - Underground Storage Tank Program
>
PR0502817
>
COMPLIANCE INFO_JUN 2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2019 4:51:00 PM
Creation date
11/8/2018 9:58:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
JUN 2016 - 2018
RECORD_ID
PR0502817
PE
2361
FACILITY_ID
FA0005584
FACILITY_NAME
VALLEY PACIFIC LODI PLANT & CARDLOCK
STREET_NUMBER
930
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04905023
CURRENT_STATUS
01
SITE_LOCATION
930 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\V\VICTOR\930\PR0502817\COMPLIANCE INFO\COMPLIANCE INFO JUN 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO JUN 2016 - PRESENT
QuestysRecordDate
9/13/2016 6:46:00 PM
QuestysRecordID
3135584
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page_4_of 7 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑ Sump Manufacturer ®Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑ Pressure ❑ Vacuum ❑Hydrostatic <br /> ❑ Other(Spec) <br /> Test Equipment Used: INCON SUMP TESTER Equipment Resolution: 0.002" <br /> Sump#T-6 87 Sump#T-7 87 Sump# Sump# <br /> Sump Diameter: 42" 42" <br /> Sump Depth: 56" 58" .� <br /> Sump Material: Fiberglass Fiberglass <br /> Height from Tank Top to Top of 12" 18" N 2 6 2018 <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 73" 14" <br /> Electrical Penetration: ,- <br /> Condition of sump prior to testing: Dry Dry ENVI f �. - <br /> Portion of Sump Tested' 2"/Penetrations 2"/Penetrations <br /> Does turbine shut down when <br /> sump sensor detectsliquid(both ®Yes ❑No ❑NA ®Yes ❑No ❑NA Elves ❑No LINA Elves ❑No DNA <br /> roduct and water)? <br /> Turbine shutdown response time 4 seconds 3 seconds <br /> Is system programmed for fail-safe <br /> shutdown?* ®Yes ❑No [INA [9 ❑Na [INA Elves ❑No ❑NA Elves ONO ❑NA <br /> Was fail-safe verified to be <br /> operational?* <br /> ®Yes ❑No DNA ®Yes LINO [INA Elves ❑No ❑NA Elves ❑No ❑NA <br /> Wait time between applying <br /> pressure/vacuum/water and starting 10 min. 10 min. <br /> test: <br /> Test Start Time: 11:05am 11:05am <br /> Initial Reading(R): 3.8814" 6.2460" <br /> Test End Time: 11:20am 11:20am <br /> Final Reading(RF): 3.8798" 6.2462" <br /> Test Duration: 15 min. 15 min. <br /> Change in Reading(RF-R,): -0.0016" +0.0002" <br /> Pass/Fail Threshold or Criteria: +/-0.002" +1.0,002" +/-0.002" +/-0.002" <br /> Test Result: ® Pass ❑Fail ®Pass ❑ Fail ❑Pass ❑Fail ❑Pass ❑ Fail <br /> Was sensor removed for testing? ®Yes ❑No DNA ®Yes ❑No ❑NA Elves ❑No DNA Elves LINO ❑NA <br /> Was sensor properly replaced and <br /> verified functional after testing? <br /> ®Yes LINO ❑NA ®Yes ❑No ❑NA Elves ❑No ❑NA Elves ❑No ❑NA <br /> Comments— (include information on repairs made prior to testing, and recommendedfollow-upforfailed tests) <br /> If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />