My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
6732
>
2300 - Underground Storage Tank Program
>
PR0231830
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:38:43 PM
Creation date
11/8/2018 9:59:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0231830
PE
2361
FACILITY_ID
FA0004030
FACILITY_NAME
THREE PALMS GROCERY
STREET_NUMBER
6732
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
10110001
CURRENT_STATUS
02
SITE_LOCATION
6732 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WATERLOO\6732\PR0231830\COMPLIANCE INFO.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
196
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENVIRONMENTAL HEALTH DEPARTMENT <br /> SAN JOAQUIN COUNTY <br /> > OG <br /> = Donaa K.Heran R.E.H.S. Unit Supervisors <br /> N 304 East Weber Avenue, Third Floor Carl Borgman,R.E.H.S. <br /> Director Mike Huggins,R.E.H.S.,R.D.I. <br /> • AI Olsen,R.E.H.S. Stockton, California 95202-2708 Douglas W.Wilson,R.E.H.S. <br /> Program Manager Telephone: (209) 468-3420 Margaret Lagorio,R.E.H.S. <br /> �iFOR Laurie A.Cotulla,R.E.H.S. <br /> Pro Fax: (209) 464-0138 <br /> Program Manager Robert McClellon,R.E.H.S. <br /> g g Mark Barcellos,R.E.H.S. <br /> July 26, 2002 <br /> Oil Equipment Service <br /> PO Box 950 <br /> San Andreas, CA 95249 <br /> RE: Three Palms Grocery, 6732 E. Hwy 88, Stockton, Underground Tank System <br /> A review of the above site indicates that the secondary piping system will not meet <br /> secondary test requirements of SB 989. This system does provide cathodic protection but <br /> will not pass.a required pressure test. The present system is not a safe suction system <br /> with the check valve at the bottom. It is recommended that this system be replaced with a <br /> new primary and secondary piping system,although the system could meet code <br /> requirements according to the State Water Resources Control Board (SWRCB)by <br /> making the system a safe suction system...This repair would require that the present <br /> secondary system be used as a method of cathodic protection. <br /> The vent piping on this system is steel piping, which is not cathodically protected. These <br /> lines are a concern due to evidence that vapor may be the method by which MTBE has <br /> been escaping into the underground. It would be recommended that the existing systems <br /> be replaced in order to prevent possible contamination in the future. Due to the fact the <br /> system was installed with a ball float, the vent line system is exempt from regulation <br /> under the Underground Tank Law H&SC Section 25281.5 (b)(1).. Therefore the EHD <br /> cannot require that this vent piping be changed as long as the vent has been properly <br /> protected with a ball float system. Indications from the SWRCB are that legislation may <br /> be passed in the future regulating these vent piping systems and they may need to be. <br /> changed in the near future. . <br /> If you have any further questions regarding the matter,please contact me at (209) 468- <br /> 3446. <br /> Environmental Health Department <br /> Doug Wilson, Supervising REHS <br /> i <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.