Laserfiche WebLink
FROM OIL EQUIPMENT PHONE NO. : 289 7545726 Nov. 21 2801 10:35RM P7 <br /> • p*V 2of2 <br /> DMA dispenser mounting flange to suspend the DMA between the island form framework.Support the <br /> bottom of the DMA with pea gravel or other suitable material.Plumb product piping and electrical <br /> conduit into DMA as required. Secure and/or tighten the valve bar and dispenser lase assemblies to <br /> prevent any movement during your pour.Pour concrete up to,but DO NOT cover,the dispenser mount <br /> flange on top of the DMA. <br /> Retro-Pit Installation and Assembly <br /> The Retro-Fit Bracket Assemblies are designed for use with the shallow DMA series. Saw cut a hole in <br /> the island surface one an one half inch(1 1/2")longer and one and one half inch(1 1/2")wider than the <br /> O.D.of the DMA Range.Example,a 11X 42 inch DMA has a approx. 11/2 inch flange malting the DMA <br /> overall 14 X 45 inches.Your saw cut hole for this size DMA would be 15 1/2 X 46 1/2 inches. Be sure to <br /> measure the overall dimensions of the DMA before cutting island surface.Cut and stub off piping and <br /> conduit so that they are vertical and can be installed through the bottom of the DMA sump while allowing <br /> enough length to pass through penetrations and connect to any extensions required.Drill corresponding <br /> Wes in DMA bottom and fit U.L.Listed penetrations.Locate DMA in position and support with pea <br /> gravel or other suitable material to correct height.Install"J"bolts and safety valve anchor bars to DMA. <br /> Plumb product piping and conduits as required.Pour concrete up to,but DO NOT cover,the dispenser <br /> mount flange on top of DMA. <br /> Dispenser Mounting and Hookup <br /> After concrete has fully cured,remove dispenser base mount bolts or"T'bolt hardware,caulk DMA <br /> • change with suitable material to prevent water intrusion,mount dispenser and connect pipinglelectrical <br /> system.Please review the enclosed details/drawings. <br /> Testing <br /> After concrete has cured and all penetrations have been sealed you may test the integrity of the sump and <br /> penetrations with water.Follow all local requirements <br /> NOTE:U.L.Listed DMA sumps require it Listed,approved,electronic monitor/alarm system to be <br /> installed for operator notification in the event of product leakage into sump area. <br /> if you have any further questions,call 1-800.688-3375,Monday-Friday,7:00 a.m.to 5:00 p.m.Pacific <br /> time. <br /> OBEY ALL LOCAL LAWS AND REGULATIONSU <br /> • <br /> samma�acs�m.+wmcroawe <br />