My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2005 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 3:06:28 PM
Creation date
11/8/2018 9:59:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2008
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\W\WEST\4040\PR0231963\COMPLIANCE INFO 2005 - 2008.PDF
QuestysFileName
COMPLIANCE INFO 2005 - 2008
QuestysRecordDate
8/2/2018 5:38:18 PM
QuestysRecordID
3952805
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S WRCB,January 2002 • • Page 5 of <br /> 7. UNDER-DISPENSER CONTAINMENT(UDQ TESTING <br /> est Method Developed By: 0 UDC Manufacturer ❑Industry Standard ❑Professional Engineer <br /> ❑Other(Spec6) <br /> Test ethod Used: ❑Pressure .. ❑Vacuum ❑Hydrostatic <br /> ❑Other(Sped) <br /> Test Equipm t Used: Equipment Resolution: <br /> v: m 6 .. ;q N •'.tl: :• s'""'�.'•" . 'u..T' 4iJ`4IN. .;k- n0.YhYhn .F: -�E_- A '.eti N ',.Hft <br /> a' UDC# UDC# UDC# # <br /> UDC Manufacturer: <br /> UDC Material: <br /> UDC Depth: <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testing: <br /> Portion of UDC Tested <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes ❑No ❑NA es o ❑NA ❑Yes ❑No ❑NA ❑Yes 0 No ❑NA <br /> roduct and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail- <br /> safe shutdown?* ❑Yes ❑No ❑ ❑Yes ❑No A ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was fail-safe verified to be <br /> operational?' ❑Yes ❑N ❑NA ❑Yes ❑No ❑NA Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test <br /> Test Start Time: <br /> Initial Re din (R�: <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: <br /> Chan a in Readin Rj): <br /> Pass/Fail Thres d or Criteria: <br /> Test Resu . ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑NJ <br /> Was sen r removed for testing? ❑Yes ❑No ❑NA ❑Yes ❑No [INA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was son properly replaced and <br /> verified functional after testis ? ❑yes ❑No ❑NA ❑Yes ❑No [INA ❑Yes ❑No ❑NA ❑Yes ❑No 11 NA] <br /> Comments—(include information on repairs made prior to testing and recommended ollow-up or failed tests) <br /> 0 C 5 . <br /> If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.