My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2005 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 3:06:28 PM
Creation date
11/8/2018 9:59:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2008
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\W\WEST\4040\PR0231963\COMPLIANCE INFO 2005 - 2008.PDF
QuestysFileName
COMPLIANCE INFO 2005 - 2008
QuestysRecordDate
8/2/2018 5:38:18 PM
QuestysRecordID
3952805
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 • • 4[ / <br /> Page -of b <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer ❑Industry Standard Professional Engineer <br /> ❑Other(Specify)Test Method Used: ❑Pressure ❑Vacuum ydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: 1,1A)of ,. c„r - Equipment Resolution: - <br /> i <br /> Sump#1 umP# Sump# Sump# <br /> Sump Diameter: <br /> Sump Depth: f <br /> Sump Material: <br /> Height from Tank To to Top of I l t t <br /> Hi est Pi in Penetration: <br /> Height from Tank Top to Lowest 1 rr <br /> Electrical Penetration: �2 <br /> Condition of sump prior to testing: <br /> Portion of Sump Tested' l J �L� LY p r <br /> Does turbine shut down when R <br /> sump sensor detects liquid(both ❑Yes ❑No kNA ❑Yes No ❑NA ❑Yes N ❑NA ❑Yes ❑No NA <br /> product and water)?* <br /> Turbine shutdown response time t p�— <br /> Is system programmed for fail-safe <br /> shutdown?* ❑Yes ❑No ;YNA ❑Yes ❑ ❑NA ❑Yes ❑` o ❑NA ❑Yes No ❑NA <br /> Was fail-safe verified to be <br /> operational?* ❑Yes ❑No )�NA ❑Yes ❑ o ❑NA ❑Yes ❑NA ❑Yes ❑ ❑NA <br /> Wait time betweenlymg <br /> presswe/vacu w1aater nd starting <br /> test: to r-tTuw4'--S <br /> Test Start Time: I Z•_3 O <br /> Initial Reading(RI): Hieb}Gyc�e <br /> Test End Time: <br /> Final Reading(RF): F s Gnc•lR . <br /> Test Duration: 36 r <br /> Change in Reading(Rt-R): s' p <br /> Pass/Fail Threshold or Criteria: 6a,�;7311",_l. <br /> Test Result: ass ❑Fail Pass ❑Fail ❑ Pass ❑F ' Pass ❑Fa I <br /> Was sensor removed for testing? 87es ❑No ❑NA es ❑No ❑NA ❑Yes ❑No ❑ es ❑No ❑ <br /> Was sensor properly replaced and es ❑No ❑NA Yes ❑No ❑NA ❑Yes ❑No ❑N N <br /> verified functional after testing? Yes ❑No ❑ <br /> Comments—(include information on repairs made prior to testing and recommended follow-up for failed tests) <br /> 'If the entre depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />