My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2005 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 3:06:28 PM
Creation date
11/8/2018 9:59:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2008
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\W\WEST\4040\PR0231963\COMPLIANCE INFO 2005 - 2008.PDF
QuestysFileName
COMPLIANCE INFO 2005 - 2008
QuestysRecordDate
8/2/2018 5:38:18 PM
QuestysRecordID
3952805
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S WRCB,January 2002 ` 0 Page Z of <br /> 4. TANK ANNULAR TESTIlVG <br /> Test Method Developed By: D Tank Manufacturer 94ndustry Standard 0 Professional Engineer <br /> 0 other(SPee(/1') <br /> Test Method Used: L Pressure Q Vacuum 0 Hydrostatic <br /> n CIA.(Sped!. <br /> Test Equipment Used; N A b(MI5 CtuA&er- -� O'h6 Equipment Resolution: <br /> Tank N UA)LD Tank# L F Tank Q Tank 1t <br /> Is Tank Exempt From Testing?' CI Yes FeNo r.Yes I?No u Yes f> 4o Yes t;No <br /> Tank Capacity: R 8D� .;`Z./_AnJ D DiyU �G,s-may <br /> Tank Material: <br /> Tank Manufacturer. m ORN <br /> Product Stored: <br /> Wait time between aPP1Y�8 <br /> Pressure/vacuum/water and <br /> starting test: <br /> Test Start Time: <br /> Initial Reading(RQ: 7.0 <br /> Test End Time: // <br /> s: <br /> Final Reading r 7 <br /> Test Duration: / / /f814 <br /> AkO <br /> Change in Reading(RF-R,):Pass/Fail Threshold or Criteria: 3 -5.3 ' f/at. <br /> Test$unit: Pass 0 Fall VPaw D Fdl Ill'Par 0 Fail ❑ "OF&HWas sensor removed for teating? D'Yes L1No [INA 8S'es 0No JNA R'Ves —No LINA ❑YeWas sensor properly replaced and <br /> verified functional after testin `r IdYcs n No �NA �'es :7 No 1"INA VVe¢ nNo 0NA : Ye <br /> Comments— (include hjormation un repairs made 1!nr ro res7ing, and recommended fuUow-up forfaded testa) <br /> secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that aro hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> tasting. {Califomis Code of Regulations,Title 23, Section 2637(a)(6)} <br />