My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2005 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 3:06:28 PM
Creation date
11/8/2018 9:59:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2008
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\W\WEST\4040\PR0231963\COMPLIANCE INFO 2005 - 2008.PDF
QuestysFileName
COMPLIANCE INFO 2005 - 2008
QuestysRecordDate
8/2/2018 5:38:18 PM
QuestysRecordID
3952805
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' Dec -21 2007 11 : 57AM HP LASERJET FAX • P. 6 <br /> SV,/RCB,January 2002 Page__q_of G <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By. 0 Sump Manufacturer C Industry Standard @'Professional Engineer <br /> 0 Other(Specify) <br /> Test Method Used: 0 Pressure 0 Vacuum LPflydrostatic <br /> 0 Other (Specify) <br /> Test Equipment Used: EAG 12tI'U6 M �?� Equip meatResolution:t,b6a <br /> Sump# Sump# Sump#(up Sump# <br /> Sump Diameter. Q r r Orr Z rr <br /> Sump Depth: oil ..3 rr Ctl t7 r, <br /> Sump Material: FI <br /> Height from Tank Top to Top of 1 r <br /> Hip <br /> i tPiping Penetration: <br /> Height from Tank Top to Lowest S r <br /> Electrical Penetration: Z rr ( �st <br /> Condition of sump prior to testing: <br /> Portion of Sump Tested' q 47W' Z" <br /> Does turbine shut down when <br /> sump sensor detects liquid(both 9'1'es 0 No [INA RO& 0 No ❑NA EeS'es 0 No 0 NA 0 Yes 0 No 0 NA <br /> product and water 7' <br /> Turbine shutdown response time ✓4TVSV, Q f V I�pT7r �' C aV7T7e*C• <br /> Is system programmed for fail-safe <br /> shutdown?` 3t-Yes 0 No 0 NA WGs 0 No 0 NA °Yes 0 No 0 NA 0 Yes 0 No 0 NA <br /> Was fail-safe verified to be <br /> operational?* ibYes 0 No 0 NA O'1'es 0 No 0 NA RScs 0 No [INA 0 Yes 0 No 0 NA <br /> Wait time between applying <br /> pressunVvacuum/water and starting <br /> test: n Y1'1,.2711 AaUF <br /> Test Start Time: 12- V /O ,Inig(RJ:Test End Time: 0�Final Reading(RF): U wcL CrteTest Duration: /(y r Mz7V / m Change in Reading(RF-R,): 3 0tKL. �/amL Pass/FailThresholdorCriteria: GCXjZ" Gpd 'rTest I et t!t W)PoSe 0 Fail B`Pass ❑Fai1 O ]'aa s ❑Fad <br /> Was sensor removed for testing? V'Yes 0 No 0 NA KrWs 0 No 0 NA f tes 0 No 0 NA 0 Yes 0 No DNA <br /> Was sensor properly replaced and Yes 12 No ❑NA <br /> verified functional after testin ? p 1 es 0 No 0 NA VV` 0 No 0 NA 0 Yes 0 No ❑NA <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed rests) <br /> 'If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See S WRCB LG-160) <br />