My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2005 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 3:06:28 PM
Creation date
11/8/2018 9:59:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2008
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\W\WEST\4040\PR0231963\COMPLIANCE INFO 2005 - 2008.PDF
QuestysFileName
COMPLIANCE INFO 2005 - 2008
QuestysRecordDate
8/2/2018 5:38:18 PM
QuestysRecordID
3952805
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
482
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank Monitorionn—Page 2 of 2 • <br /> VL DISPENSER MONITORING <br /> MONITORING OF AREAS BENEATH DISFENSER(S)IS PERFORMED USING THE FOLLOWING MEHOD(S)(Check all that apply) Msa. <br /> ❑ 1.CONTINUOUS ELECTRONIC MONITORING OF UNDER DISPENSER CONTAINMENT(UDC) <br /> PANEL MANUFACTURER: nisi. MODEL#: M's" <br /> LEAK SENSOR MANUFACTURER W3' MODEL#(S)! Nd4. <br /> WILL DETECTION OF A LEAK INTO THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? ❑ a YES ❑ IS.NO MSS <br /> WILL A L1DC LEAK ALARM TRIGGER AUTOMATIC PUMP SHUTDOWN? 0 a.YES ❑ Is.NO ""' <br /> WILL FAILURFJDISCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? ❑ B.YES ❑ Is,NO Mr <br /> ❑ 2.MECHANICAL ASSEMBLY(mg,,FLOAT AND CHAIN ASSEMBLY)IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK <br /> ASSEMBLY MANUFACTURER: NUB. MODEL4(S): Mso• <br /> ❑ 3.VISUAL MONITORING DONE: ❑ a,DAILY ❑ b.WEEKLY(Repo mmey,q m"I) nes. <br /> ® 4.NO DISPENSERS <br /> ❑ 99.OTHER S ccify) Mst. <br /> VII. ENHANCED LEAK DETECTION <br /> ❑ 1.WE HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK M'ro <br /> DETECTION(ELD)FOR THE UST(S)COVERED BY THIS PLAN,PER 23 CCR§2644,1,BLD IS PERFORMED EVERY 36 MONTHS AS REQUIRED <br /> VIII. TRAINING <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) man, <br /> 1. 0 THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) <br /> 2. 0 OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required) <br /> 3. ❑ THE FACILITY'S BEST MANAGEMENT PRACTICES(Required as of3anuary 1,2005) <br /> 4. ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br /> 5. ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW <br /> 6. ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "IiANDBOOK FOR TANK OWNERS . MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION" <br /> 7. ❑ SWRCB PUBLICATION:"WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS" <br /> 99. ❑ OTHER(Specify): stun. <br /> Personnel with UST monitoring responsibilities are familiar with all of the above documents relevant m thcirjob duties and can aeceaa those documents when needed.. <br /> By January 1,2005,thin facility will have a'•,Oasignated UST Operator"who has passed the California UST Sytem Operator Exam administered by the International <br /> Code Council(ICC). By July 1,2005,and annually thereafter,the "Designated UST Opcmar will train facility employees in the proper operation and maintenance <br /> of the UST systems.This training will include,but is not limited to,the following: <br /> D Operation of the UST systems in a manner eoasietmt with the facility's best management practices. <br /> 9 The bcility employee's role with regard to the leak detection equipment, <br /> ➢ The faciliry employee's role with regard to spills end ovcrfi0s, <br /> i Whom to contact for amergerrcies and leak detection alarms. <br /> For facility employees hired on crafter July 1,2005,the initial training will be conducted within 30 days of the date of him, <br /> IX. COUNTS/ADDITIONAL INFORMATION <br /> please use this section to include any additional UST system monitoring-related information(eg-additional information.required by your local agency): Mss. <br /> Note regarding Section X.Pending cart1fication of a Designated UST Operator,the following person has authority for performing the monitoring <br /> activities and maintaining leak detection equipment covered by this plan. NAME:Michelle Le JOB TITLE! Env Specialist <br /> Overfill for this tank Is an audible/visual alarm set at 90%. Additionally, quanitities of less than 25 gallons are <br /> delivered into the tank at any one time. <br /> X. PERSONNEL RESPONSIBILITIES <br /> AS OF JANUARY 1, 2005, THE "DESIGNATED UST OPERATOR" IDENTIFIED IN SECTION RI OF THE CURRENT UST OPERATING PERMIT <br /> APPLICATION—FACILITY FORM WILL HAVE ULTIMATE AUTHORITY FOR PERFORMING THE MONITORING ACTIVITIES AND MAINTAINING <br /> LEA)t DU=nON EQUIPMENT COVERED BY THIS PLAN, AND WILL PERFORM AND DOCUMENT MINIMUM MONTHLY VISUAL INSPECTIONS <br /> OF THE FACILITY'S VST SYSTEMS IN ACCORDANCE WITH 23 CCR j 2715(b). <br /> XI. OWNER/OPERATOR SIGNATURE <br /> CERTIFICATION: L certify that the information provided herein is true and accurate to the best of my knowledge <br /> 0 PERATOR S2A RE REPRESENTING DATE nrot. <br /> ❑Owner Moo. <br /> ❑Operator December 4 2007 <br /> OWNER/OPERATOR NAME(print):U O WNEWOPERATOR TITLE: Not. <br /> Michelle Le Environmental Specialist <br /> (Agency U.ee Only) This plan has been reviewed and: pproved 0 Approved With Conditions �7❑ i ved <br /> Local Agency Signature: /� Date: 1� <br /> Commrntd5pccial Cnndinons: ' <br /> UN-022A•315 www.unldoes.org Rev.10114103 <br />
The URL can be used to link to this page
Your browser does not support the video tag.