My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2009 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 2:59:06 PM
Creation date
11/8/2018 9:59:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2015
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\W\WEST\4040\PR0231963\COMPLIANCE INFO 2009 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2009 - 2015
QuestysRecordDate
8/2/2018 4:41:39 PM
QuestysRecordID
3952362
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
345
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9255517888 Une 1 14:13:51 12-12-2013 3 7 <br /> ®6F1'11fR-RYAN INC. *Job# 20.592983 <br /> SWRCB,January 2002 Pee 2 of 5 <br /> Page _ <br /> 4.TANK ANNULAR TESTING RECEIVED <br /> Test Method Developed By: Tank Manufacturer Industry Standard Professional Engineer <br /> Other(specify) DEC 12 2013 <br /> Test Method Used: Pressure Vacuum Hdrostatic <br /> Other(specify) tNVIRON L <br /> Test Equipment Used: Vacuum Cau e Equipment Resolution:ILALTH RARTMEN <br /> Tank#1 Tank#2 Tank#3 Tank# <br /> Is Tank Exempt Form Testing? 1) Yes Yes Yes Yes No <br /> Tank Capacity: 10,000 10,000 700 <br /> Tank Manufacturer. Xerxes Xerxes Xerxes <br /> Product Stored: Reg Prem W.011 <br /> Wait time between applying <br /> Pressuretvacumn/water and 10min 10min 10min <br /> starting test: <br /> Test Stan Time: 9:15 10:30 11:30 <br /> Initial Reading Ri); '-7" '-T' '-T" <br /> Test End Time: 10:15 11:30 12:30 <br /> Final Reading(Rf) '-T' '-T' '-7" <br /> Test duration: 1 hr lhr lhr <br /> Change in Reading(Rf-Ri): 0 0 0 <br /> Pass/Fail Threshold or Criteria: 0 0 0 0 <br /> Test Results:, X: ss I Fail x Pass PailX Pass Fall - Pass - Fail <br /> Was sensor removed for testing? NoNA No NA No NA Yes No NA <br /> Was sensor properly replaced and Yes No Yes No Yes No Yes No NA <br /> verified functional after testing? <br /> Comments-(include information on repairs made prior to testing,and recommend follow-up or(ailed tests) <br /> 1)87 <br /> 2)91 <br /> 3)W.oil <br /> (1) Secondary containment system where the continuous monitoring automatically monitors both the primary and secondary <br /> containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23,Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.