Laserfiche WebLink
eo Con Rd, ' 1"_r� <br /> EDMUND Q.BROWN JR. <br /> �'-0'• aarepnon <br /> M�ATEIARY FOR UEY <br /> C <br /> Water <br /> Boards ENVIR0N1dENin PROTECTpN <br /> State Water Resources Control Board <br /> January 23, 2013 <br /> Mr. Don Mukai <br /> S. Bravo Systems, Inc. <br /> 2929 Vail Avenue <br /> Commerce, CA 90040 <br /> Dear Mr. Mukai: <br /> REVISED APPROVAL OF THE DISPENSER CONVERSION FRAME, MODEL CONV- <br /> 132000/CONY-82000-OPP AS AN UNDER-DISPENSER SPILL CONTAINMENT OR <br /> CONTROL SYSTEM TO INCLUDE PROVISIONS FOR THE CONV RETROFIT PLATE <br /> KIT INSTALLATION <br /> This letter is in response to your application for approval of the revised S. Bravo <br /> Systems, Inc. (Bravo) Dispenser Conversion Frame, model CONY-B2000/CONV- <br /> B2000-OPP (CONY-B2000) including the CONY Retrofit Plate Kit. This revised <br /> approval letter of the Bravo Dispenser Conversion Frame CONV-132000 including the <br /> CONV Retrofit Plate Kit supersedes the State Water Resources Control Board's (State <br /> Water Board) approval letter dated April 8, 2008. <br /> Description of the CONV-B2000 <br /> The CONY-132000 is a conversion frame designed to allow larger dispensers to be <br /> installed above smaller existing under-dispenser containment (UDC). When piping <br /> within the dispenser falls outside the footprint of the UDC, the CONV-132000 is designed <br /> to direct any leaking product into the UDC where it will be contained and detected, as <br /> required by California regulations. <br /> The CONV-132000 is fabricated of galvannealed and epoxy powder coated 12 gauge <br /> (0.093"thickness) steel. It is designed to prevent interference of the UDC water splash <br /> guard, and includes a water splash guard to prevent water intrusion. The CONV-132000. <br /> provides angles to drain releases back into existing UDC using a weir system of <br /> drainage. Enclosure 1 shows a typical drawing of the CONV-132000. Exact dimensions <br /> are determined when an owner or operator sends UDC and dispenser information to <br /> 1 For a detailed explanation of the requirements for dispenser piping refer to the State Water Board's <br /> December 21,2007 letter"Clarification of Existing Regulations for Under-Dispenser Containment:" <br /> CHARLES R, Honm,CHAIRMAN i THOMAS HOWARD, EXECUTIVE DIRECTOR <br /> 1001 I Streot,Sacramento.CA 05814 1 Mating Address:P.O.Box 100,Sacramento,CA 9581201 DO I www.waterboarcls.ca.gov <br /> ��RECYCLED WER <br />