Laserfiche WebLink
Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at httpR/www.waterboards.ca.gov <br /> .) <br /> MONITORING SYSTEM CERTIFICATION SEP 2 8 2017 <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code,•Chapter 16,Division 3, Title 23,California Code of Regulations _ <br /> This form must be used to document testingand servicing of monitoring equipment.A s arate certification or report T �_TH <br /> g gseparate p � p���bti'pfep`azed for each ' <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to t0mk sy,L' awner/operator. The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. �-'� ° JA, ' a <br /> A. General Information <br /> Facility Name: Pacific Gas and Electric Company Facility ID: PGE095 <br /> Site Address: 4040 West Ln. Cite: Stockton Zip: 95204 <br /> Facility Contact Person: Alex Steele Contact Phone No.: 209-736-6426 <br /> Make/Model of Monitoring System: Veeder-root TLS-350 Date of Testing/Servicing: 09/13/2017 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/seryiced: <br /> Tank ID: T1:Unleaded Tank ID: T2:Diesel <br /> 0 In-Tank Gauging Probe. Model: 847390-107 In-Tank Gauging Probe. Model: 847390-107 <br /> ❑ Annular Space or Vault Sensor. Model: 794390-420 Annular Space or Vault Sensor. Model: 794390-420 <br /> ❑ Piping Sump/Trench Sensor(s). Model: 794380-208 piping Sump/Trench Sensor(,). Model: 794380-208 <br /> ❑ Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> 0 ElectronicL Line Leak Detector. Model: Red Jacket Electronic Line Leak Detector. Model: Red Jacket <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Sectio n k on Page 2) ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Waste Oil i' 41 Tank ID: Hydrolic Fluid <br /> ❑ In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> QAnnular Space or Vault Sensor. Model: 794390-420 0 Annular Space or Vault Sensor. Model: 794390-420 <br /> * Piping Sump/Trench Sensor(s). Model: 794380-208 ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(,). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: — E]Electronic Line Leak Detector. Model: <br /> I❑X Tank Overfill/High-Level Sensor. Model 794390-420 R Tank Overfill/High-Level Sensor, Model: 794390-420 <br /> F] Other(specify equipment type and model in Section E on Page 2). Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: Unleaded 1-2 Dispenser ID: Unleaded 3-4 <br /> Dispenser Containment Sensor(s). Model: 794380-208 ❑X Dispenser Containment Sensor(s). Model: 794380-208 <br /> 0 Shear Valve(,). M Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Diesel Dispenser ID: <br /> ZDispenser Containment Sensor(s). Model: 794380-208 ❑Dispenser Containment Sen sor(s). Model: <br /> QShear Valve(s). ❑Shear Valve(,). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers' checklists)necessary to verify that this information is correctand <br /> a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of <br /> the report;(check all that apply) : Q System set-up 0 Alarm history report <br /> Technician Name(print): Garrett Warren Signature: Cfazw&2f/azam <br /> Certification No B42126 License. No.: 588098 <br /> Testing Company Name:TAIT Environmental Services,Inc. Phone No.: 714560-8222 <br /> Testing Company Address:701 N Parkcenter Dr.,Santa Ana,CA,92705 Date of Testing/Servicing: 09/13/2017 <br />