My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 2:56:03 PM
Creation date
11/8/2018 9:59:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\W\WEST\4040\PR0231963\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
7/23/2018 8:37:33 PM
QuestysRecordID
3946151
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing a r�-=,tl <br /> C" <br /> tl- 2' it (0A ILZdT %:s. <br /> RE <br /> Software Version Installed: 120.02 <br /> SEP 2 S 2017 <br /> Complete the following checklist: <br /> ❑X Yes ❑ No* Is the audiblealann operational? _nt%nonryll,,li,1--stidTAL HLA <br /> 0 yes ❑No* Is the visual alarm operational'? 0 EPARTMUIT <br /> ❑X Yes ❑No* Were all sensors visually inspected,functionally tested,and confirmed operational. <br /> ❑X Yes ❑No* Were all sensors installed at lowestpoint of secondary containment and positioned so that other equipment <br /> will not interfere with their <br /> ro r o ration? <br /> ❑ Yes ❑No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g.modem) <br /> ❑X N/A operational'? <br /> ❑X Yes ❑ No* Fur pressurized piping systems, does the turbine automatically shut down if the piping secondary <br /> ❑N/A containment monitoring system detects a leak,fails to operate,or is electrically disconnected?Ifyes:which <br /> sensors initiate positive shut-down?(Check all that apply) <br /> ❑X Sump/Trench Sensors; ❑X Dispenser Containment Sensors. Did you confirm positive shut-down <br /> due to leaks and sensor failure/disconnection? <br /> 0 Yes; ❑N o. <br /> ❑ Yes ❑No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no <br /> mechanical overfill prevention valve is installed),is the overfill waming alarm visible and audible at the <br /> 0 N/A tank fill point(s)and operating properly?If so,at what percent of tank capacity does the alarm trigger? <br /> oda <br /> Dyes* ❑X No Was any monuoirng equipment replaced? II'\CS.idem( specific sensors,probes. or othu equipment <br /> replaced and Inst the manufacturer name and model Iter all replacement parts iii 1)cction I-..(clow. <br /> F❑Yes* ❑X No Was liquid found inside any secondary containment systems designed as dry systems`? (Check all that <br /> ul Ny) ❑Product: ❑Water.If yes.describe causes in Section F. belrnv. <br /> ❑X 1"e; ❑ No* Was monitonn�- s stem set-up re\'ieviced to ensurV proper settings? Attach et up reports,if applicable <br /> 0 yeti ❑No~ [s all monitoring equipment operational per manufacturer's speei i1CaLIonS? <br /> *In Section E below,describe how and when these deficiencies were orwill be corrected. <br /> E. Comments: <br /> L 11 Waste Oil tank Overfill sensor 794390-420: Certified. <br /> L 12 Hydraulic Tank Gauge sensor 794380-208: Certified. <br /> L14 Motor Oil Annular 794390-420: Certified. <br /> L15 Vent Sump 794380-208: Certified. <br /> L16 Waste Oil drain pan. 794380-208: Certified. <br /> Both the Unleaded UST and the Diesel UST are equipped with mechanical overfill prevention valves. <br />
The URL can be used to link to this page
Your browser does not support the video tag.