My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 2:56:03 PM
Creation date
11/8/2018 9:59:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\W\WEST\4040\PR0231963\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
7/23/2018 8:37:33 PM
QuestysRecordID
3946151
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tank Manufacturer ❑X Industry Standard ❑ Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑X Vacuum ❑Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: 4"dial gauge Equipment Resolution: .2 <br /> 111111[Wnleaded Diesel Waste Oil <br /> Is Tank Exempt From Testing?' ❑Yes E]No ❑Yes FX-IN ❑Yes ONo ❑)'es ❑ No <br /> Tank Capacity: 10,000 10,000 1,000 <br /> Tank Material: Fiberglass Fiberglass Fiberglass <br /> Tank Manufacturer: Xerxes Xerxes Xerxes <br /> Product Stored: Unleaded Diesel Waste Oil <br /> Wait time between applying <br /> pressure/vacuum/water and 15 Min 15 Min 15 Min <br /> starting test: <br /> Test Start Time: 11:00 am 11:00 am 2:00 pm <br /> Initial Reading(Rj): -10"hg -10"hg -10"hg <br /> Test End Time: 12:00 pm 12:00 pm 3:00 pm <br /> Final Reading(RF): -10"hg -10"hg -10"hg <br /> Test Duration: 1 hour 1 hour 1 hour <br /> Change in Reading(RF-RI): 0 0 0 <br /> Pass/Fail Threshold or Criteria: 0 0 0 <br /> Test Result: 0 Pass ❑Fail 0 Pass ❑Fail El Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? ❑X Yes ❑No ❑NA ❑Yes El No❑NA ❑X Yes❑No❑NA ❑Yes❑No❑NA <br /> Was sensor properly replaced and ❑Yes [ENo [DNA <br /> verified functional after testing? El Yes❑X No El NA ❑Yes ONo❑NA ❑Yes❑No❑NA <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> sensor was removed for testing and put back after finish. <br /> ' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23,Section 2637(a)(6)1 <br />