My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1998-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1434
>
2300 - Underground Storage Tank Program
>
PR0231465
>
COMPLIANCE INFO 1998-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/20/2023 10:49:21 AM
Creation date
11/8/2018 10:02:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2003
RECORD_ID
PR0231465
PE
2361
FACILITY_ID
FA0003739
STREET_NUMBER
1434
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1434 W Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\Y\YOSEMITE\1434\PR0231465\COMPLIANCE INFO 1998-2003.PDF
QuestysFileName
COMPLIANCE INFO 1998-2003
QuestysRecordDate
6/26/2017 11:25:13 PM
QuestysRecordID
3467494
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
268
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
When all of the conductors feeding the dispensers have been properly labeled, <br /> shut off all power feeding circuits in the wiring trough. Locate the first set of <br /> i conductors and, using the meter, make sure all of the power is off. After making <br /> certain that all power is off, cut each of the conductors at an appropriate spot and <br /> connect each side of the conductor as shown on the wiring diagram below: <br /> Use the black and white conduc- LI from Panel Black <br /> tors to break the hot and neutral Black Comas Razing: 16A@250V <br /> @eds from the circuit breaker LI to Da enser <br /> panel to the dispenser. The N from Panel White <br /> black and white wires connect Contan Ratings: 16A @250V <br /> to relays that can handle up to N to Dispenser White <br /> 16 amps of current per contact. <br /> Orange <br /> Use the 4 additional contacts to <br /> Orange Contact Ratings: 8A @250V <br /> break other I IOV conductors to <br /> dispenser,such as STP control Blue <br /> wiring and dispenser lights. Contact Ratings: 8A @250V <br /> Blue <br /> If there aro more than 6 con- Yellow <br /> doctors,contact Beaudreau Contact Ratings: 8A @250V <br /> Customer Service at 1-800- Yellow <br /> 739-4435 and order Partll522R- <br /> 2. This relay unit will provide Purple <br /> for up to 4 additional conduc- Contan Ratings: 8A @250V <br /> tors. Pu le <br /> To avoid shorting out relay channels keep power off to Serial Relay Board <br /> until all connections described below are made. <br /> Run the 522 Relay box control cables through appropriate conduit(see page 5) to the 522 <br /> Serial Relay Interface System. Locate the a terminal block labeled"TBI" located next to <br /> the red LED labeled"LED 1" (see page 6). Connect the 522 Relay box control cable for <br /> Dispenser 1 to TB 1 (see wiring diagram on page 6) and so on. Once all connections have <br /> been made, power to the 522 Serial Relay Interface System can be turned on. When <br /> power is restored, the red LEDs on both the board and on the 522 Relay Box relays <br /> should be lit. If LEDs on the interface board are not lit, cycle power to the board. If <br /> LEDs on the 522 Relay Boxes are not lit, check to make sure polarity is correct. <br /> 5. Communicating to Veeder Root-TLS-350 <br /> The 522 Remote Monitoring System has a single relay output(see page 7-8) for <br /> communicating alarm information to the Veeder Root TLS-350 through anInput/Output <br /> Combination Module (use Veeder Root Part#323900-00x). Equiva specificies that the <br /> TLS-350 receive fuel,high water, and impact alarms and the 522 Remote Monitor is <br /> programmed to send those alarms via the relay output. Using 18 gauge or smaller <br /> conductors, connect per Veeder-Root instructions to the Veeder-Root 1/0 Module. The <br /> TLS-350 input should be identified as "Beaudreau System". <br /> Page 11 <br />