3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 4:48:12 PM
Creation date
11/8/2018 10:21:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2006-2012.PDF
QuestysFileName
COMPLIANCE INFO 2006-2012
QuestysRecordDate
7/5/2017 10:08:33 PM
QuestysRecordID
3482644
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer ®Industry Standard ❑Professional Engineer <br /> ❑.Other(Spec) <br /> Test Method Used: ❑ Pressure ❑Vacuum N Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Wayne Perry Inc. Equipment Resolution: -0007" <br /> Sump# .4;7-1- 1 Sump# T7- 2- Sump# 9/ Sump# <br /> Sump Diameter: <br /> Sump Depth: S „ <br /> Sump Material: ' < xa <br /> Height from Tank Top to Top of „ <br /> Highest Piping Penetration: 27 <br /> Height from Tank Top to Lowest q „ <br /> Electrical Penetration: / Z� <br /> Condition of sump prior to testing: vFc Z>k <br /> Portion of Sum Tested 2"ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVB HIGHEST 2"ABOVE HIGHEST <br /> P PIPING PENETRATION PIPING PENETRATION PIPING PENETRATION PIPING 1'ENETRATTON <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes []No ®NA <br /> product and water)?* <br /> Turbine shutdown response time NA NA NA <br /> Is system programmed for fail-safe ❑Yes ❑No ®NA ❑Yes ❑No N NA ❑Yes ❑No ®NA ❑Yes ❑No R NA <br /> shutdown?* <br /> Was fail-safe verified to be []Yes ❑No ®NA ❑Yes []Nu ®NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA <br /> o rational? <br /> Wait time between applying <br /> pressurelvacuum/water and starting 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> test: <br /> Test Start Time: ovz T--"57 9'17 <br /> Initial Reading(R): EZ 6%-&9s-,71 /• 7 2 zI <br /> Test End Time: /v,•19 50.',17- 1 1 9=y 2 <br /> Final Reading(RF): h!62 S"v 9,5*v 1 1/. -Zz/ <br /> Test Duration: 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min <br /> Change in Reading(RF-RO: '-wozS 000 2 sip <br /> Pass/Fail Threshold or Criteria: -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 <br /> z <br /> Was sensor removed for testing? EJ-Yes ❑No ❑NA 13-Yes ❑No ❑NA 0-Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and [ 'Yes ❑No ❑NA E3-Yes ❑No ❑NA [3-Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testing? <br /> COTttMentS-(include information on repairs made prior to testing and recommended follow-up forfailed tests) <br /> Costco#658 <br /> 3250 W Grant Line <br /> Tracy,Ca 95304 <br /> Niclt Harvey <br /> #09009 SB 989 <br />