My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 4:48:12 PM
Creation date
11/8/2018 10:21:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2006-2012.PDF
QuestysFileName
COMPLIANCE INFO 2006-2012
QuestysRecordDate
7/5/2017 10:08:33 PM
QuestysRecordID
3482644
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J Page of <br /> 7.UNDER-DISPENSER CONTAINMENT(UDC)TESTING <br /> Test Method Developed By: UDC Manufacturer ❑ Industry Standard ® Professio7Engine=erOther(Specify) <br /> Test Method Used: Pressure ❑ Vacuum D Hydrostat <br /> Other(Spec) <br /> Test Equipment Used: Wayne Perry Inc. See Attached Testing Results Equipment Resolution: .00007 <br /> Under-Dispenser Containment Number Below <br /> r-2 3- <br /> UDC Manufacturer. <br /> UDC Material: P <br /> UDC Depth: 13" 73" Z 2 " ��" z 5 <br /> " <br /> Height from UDC Bottom to Top 9 " 9 " q " 7 " 7 - <br /> of <br /> "of Highest Piping Penetration: / <br /> Height from UDC Bottom to 3 " 3 " " 3 30 <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Ok PK cPk <br /> testi❑ <br /> 2"Above Highest 2"Above Highest 2"Above Highest 2"Above Highest <br /> Portion of UDC Tested' Penetration Penetration Penetration Penetration <br /> Does turbine shut down when ❑Yes D No NA® ❑Yes❑ No NAM ❑Yes❑ No NA® ❑Yes❑ No NAN <br /> UDC sensor detects liquid. <br /> Turbine shutdown response time D Yes❑ No NA® ❑Yes❑ No NAM ❑Yes❑ No NA® ❑ Yes❑ No NAM <br /> Is system programmed for fail- [:]Yes❑ No NA® ElYes ElNo NA® ❑Yes ElNo NAN ❑Yes❑ No NAM <br /> safe shutdown? <br /> Was fail-safe verified to be ❑Ym❑ No NAM ❑Yes❑ No NA® ❑Yes❑ No NAN ❑Yes❑ No NAM <br /> o eratiol <br /> Wail time between applying <br /> pressurelvacuum/water and 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> starting test <br /> Test Start Time: Yt V 2.' G / z //.'4/7- <br /> Initial <br /> Initial Reading(RJ: �:Q �ti� / 6 9 . 3 z9/ /• Y7� t� Y3 <br /> Test End Time: /�'•'Sf 1 S7 <br /> Final Reading(RF): 6 7 7Z 6 /. 77/ O 3b <br /> Test Duration: 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min IS Min <br /> Change in Reading(RFRJ: ,✓�vzt' D�fJ�� •vvo ����/ <br /> Pass/Fail Threshold or Criteria: -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 0.0020 0.0020 <br /> lal E! <br /> . L k Re n,E MEMO <br /> Was sensor removed for testing? El-Yes L1 ❑ f� <br /> No NA 'Yes ElNo NAE] 8'Yes❑ No NAD B-Yls❑ No <br /> Was sensor properly replaced and Q,Yes❑ No NAP E9'Y-es❑ No NAD B-Yes❑ No NAD Q"7fes❑ No NAD <br /> verified functional after testing? <br /> Comments (include information on repairs made prior to testing and recommended fool-low-up for faiiledates_ts) <br /> I z a...,,...0 ,fi / &Al , A, l7.�v�.�'-t <br /> Costco#658 <br /> 3250 W. Grant Line <br /> Tracy,Ca 95304 <br /> Nick Harvey <br /> #09009 SB 989 <br />