My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2021 4:34:29 PM
Creation date
11/8/2018 10:21:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2013-2015.PDF
QuestysFileName
COMPLIANCE INFO 2013-2015
QuestysRecordDate
7/5/2017 11:14:25 PM
QuestysRecordID
3483232
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
U / Page 2 of 10 <br /> 1. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tank Manufacturer ®Industry Standard ❑Professions n <br /> ❑Other(Specify) FEY 2 3 20!5 <br /> Test Method Used: ❑Pressure ®Vacuum ❑Hydrostatic <br /> ❑other(Specify) - <br /> ENVIRONME L <br /> Test Equipment Used: See attached testing procedures Equipment ResolutionHFA1TH rn:PaanuF <br /> ENRL <br /> Tank# Tank# Tank# Tank# <br /> Is Tank Exempt From Testing?' ❑Yes NNo ❑Yes NNo ❑ Yes NNo ❑Yes ❑No <br /> Tank Capacity: <br /> Tank Material: Fiberglass <br /> Tank Manufacturer: <br /> Product Stored: <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test: <br /> Test Start Time: <br /> Initial Reading(Ri): <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: <br /> Change in Reading(RF-RO: <br /> Pass/Fail Threshold or Criteria: 0.00 0.00 0.00 0.00 <br /> Test Result: N Pass [--]Fail N Pass ❑Fail N Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? ❑Yes NNo[:INA [-]Yes NNo ❑NA ❑Yes NNo❑NA ❑Yes[:]No❑NA <br /> Was sensor properly replaced and <br /> verified functional after testing? <br /> ❑Yes❑No[DNA ❑Yes❑No NNA ❑Yes❑No NNA ❑Yes❑No❑NA <br /> CllnlmentS—(include information on repairs made prior to testing, and recommendedfollow-up forfailed tests) <br /> Annulars— WET <br /> All Additive Tank components are monitored except spill buckets <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. (California Code of Regulations,Title 23,Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.