My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2021 4:34:29 PM
Creation date
11/8/2018 10:21:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2013-2015.PDF
QuestysFileName
COMPLIANCE INFO 2013-2015
QuestysRecordDate
7/5/2017 11:14:25 PM
QuestysRecordID
3483232
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
aJ Page 7 of 10 <br /> 7. UNDER-DISPENSER CONTAINMENT C TESTIN <br /> Test Method Developed By: ❑UDC Manufacturer ®Industry Standard ❑P f <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum ®Hydrosta 2015 <br /> ❑ Other(Specify) <br /> Test Equipment Used: See attached testing procedures. Equipment Resoluuo v ,,. <br /> LDDC#9/10 UDC#11/12 UDC# UDC # <br /> UDC Manufacturer: <br /> UDC Material: Plastic Plastic <br /> UDC Depth: 25" 25" <br /> Height from UDC Bottom to Top 8" 8" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 5" 5" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Fair Fair <br /> testing: <br /> Portion of UDC Tested Above highest Above highest Above highest Above highest <br /> penetration penetration penetration netraaon <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both E]Yes E]No N NA ❑Yes E]No N NA [:1 Yes El No N NA El Yes El No N NA <br /> product and water <br /> Turbine shutdown response time <br /> Is system programmed for fail- <br /> safe shutdown? <br /> El [:]No N NA [:]Yeses ElNo N NA ElYes ElNo N NA ElYes [-]No N NA <br /> Was fail-safe verified to be ❑ <br /> operational?* Yes E]No N NA [—]Yes[:]No N NA [-]Yes [-]No N NA ElYes ElNo N NA <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test <br /> Test Start Time: 2:24pm 3:05pm <br /> Initial Reading(RI): 1.3628 1.3955 <br /> Test End Time: 2:39pm 3:20pm <br /> Final Reading(RF): 1.3628 1.3956 <br /> Test Duration: 15 min 15 min 15 min 15 min <br /> Chane in Reading(Pr-R : 0.00004 0.00011 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: Pass LJ Fail Pass all LJ Pass Ll Fail Pass Fail <br /> Was sensor removed for testing? ®Yes❑No ❑NA I NYes[:)No ❑NA ®Yes❑No ❑NA I ®Yes❑No❑NA <br /> Was sensor properly replaced and <br /> verified functional after testing? ®Yes❑No❑NA NYes[:]No❑NA NYes❑No ❑NA Yes❑No❑NA <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> u If the entire depth of the UDC is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(e)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.