My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2021 4:34:29 PM
Creation date
11/8/2018 10:21:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2013-2015.PDF
QuestysFileName
COMPLIANCE INFO 2013-2015
QuestysRecordDate
7/5/2017 11:14:25 PM
QuestysRecordID
3483232
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVEL <br /> JUN 08 2015 <br /> 7. UNDER-DISPENSER CONTAINMENT (UDQ TESTING <br /> Test Method Developed By: ❑UDC Manufacturer ❑Industry Standard ❑Pf40M OWW NTA I <br /> ❑Other(Specify) v •T..j n�qn oru Ce�� <br /> Test Method Used: ❑Pressure ❑Vacuum ❑Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Equipment Resolution: Inches <br /> UDC# 1/2 UDC# 5/6 UDC# UDC# <br /> UDC Manufacturer: <br /> UDC Material: Plastic Plastic <br /> UDC Depth: 35" 30" <br /> Height from UDC Bottom to Top 8" 8" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 5" 5" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> Fair Fair <br /> testis <br /> Portion of UDC Tested 2"above highest Penetration 2"above highest penetration <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both N/A N/A <br /> product and water <br /> Turbine shutdown response time N/A N/A <br /> Is system programmed for fail- <br /> safe shutdown? ❑Yes ElNo m NA ❑Yes ❑No m NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was fail-safe verified to be ❑Yes ❑No p NA ❑Yes ❑No p NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 15 minutes 15 minutes <br /> starting test <br /> Test Start Time: 10:41am 10:21 am <br /> Initial Reading (Rt): 1.2819 Inches 4.2807 Inches Inches Inches <br /> Test End Time: 10:56am 10:36am <br /> Final Reading(R,): 1.2823 Inches 4.2808 Inches Inches Inches <br /> Test Duration: 15 min 15 min <br /> Chane in Reading(R,-R,): 0.0004 0.0001 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 <br /> Test Result: p Pass ❑Fail p Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? ®Yes ❑No ❑NA ®Yes ❑No ❑NA ❑Yes ❑No ❑NA []Yes ❑No ❑NA <br /> Was sensor properly replaced and m Yes ❑No ❑NA m Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br /> Repairs made pursuant to San Joaquin County EH Permit SR0071768 <br /> Inspector Michelle Henry present during testing <br /> 6 Month post repair test required - due by 11/27/15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.