My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/28/2023 9:08:35 AM
Creation date
11/8/2018 10:21:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2016 - PRESENT.pdf
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
416
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5. SECONDARY PIPE TESTING <br /> 'fest Method Developed By: ❑ Piping Manufacturer ® Industry Standard © Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ® Pressure ❑ Vacuum p Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used: Test reducer boots,air•:compressoe and gauges 1 quiptuent Resolution:0.5%of span <br /> 87SI 87 Manifold V-RlVcnt <br /> Piping Material: Fiberglass Plastic Fiberglass <br /> Piping Manufacturer: AO Smith Environ AO Smith <br /> Piping Diameter: 3" 2" 4++ <br /> Length of Piping Run: 15' 15' 240' <br /> Product Stored: 87 87 NA <br /> Method and location of <br /> piping-run isolation: Reducer BootslFittiugs Reducer BootslFittings Reducer Boots/Fittings <br /> Wait tithe between applying <br /> press urelvacuumhvater and 10 minutes 10 minutes 10 minutes <br /> starting test: <br /> Test Start Time: 08:30 AM 08:30 AM 08:30 AM <br /> Initial Reading(R): 5 5 5 <br /> Test End Time: 09:30 AM 09:30 AM 09:30 AM <br /> Final Reading(Ry): 5 5 5 <br /> Test Duration: 60 Min 60 Min 60 Min <br /> Change in Reading(Rr-will): 0 0 0 <br /> Pass/Fail Threshold or <br /> Criteria: No Detectable Loss No Detectable Loss No Detectable Loss <br /> Test Result: Pass Pass Pass <br /> Comments—(ii?cltide ii?far)natioi7.oi7 i-epairs i7?ade pi•lor to testi?ag, ai7d i-ecoiyiuierrded folloti,-tip for failed tests) �T <br /> OCT 2 6 2017 <br /> PERMITISERVICES <br />