ELECTRICAL SITE NOTES CONTRACTOR NOTES <br /> AREA OUTLINED IS A CLASS 1, DIVISION 1(BELOW GRADE AND DISPENSER 1 ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE <br /> HOUSING) AND CLASS 1 DIVISION 2(ABOVE GRADE) HAZARDOUS AREA, ELECTRICAL PORTION OF THE PROJECT TO PROVIDE A COMPLETE <br /> AND OPERATIONAL ELECTRICAL SYSTEM, EXCEPT THAT THE <br /> AND SHALL CONFORM TO NEC ART, 500, 501 , 514, AND NEPA 30A. <br /> ALL CONDUITS ENTERING OR LEAVING THIS AREA SHALL HAVE SEAL-OFFS PROVISIONS FOR OWNER-SUPPLIED EQUIPMENT SHALL ONLY BE <br /> FITTINGS ON BOTH ENDS OF THE RUN, CONDUIT INSTALLED IN, ENTERING, COMPLETED TO THE POINT INDICATED ELSEWHERE ON THE <br /> PASSING THRU AND LEAVING THIS AREA INCLUDING ALL RISERS AND LAST 2' OF DRAWINGS. <br /> I U.G. RUN TO THE POINT OF CONNECTION TO THE ABOVE GROUND CONDUIT 2 ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONFORMITY TO <br /> SHALL BE THREADED RIGID METAL CONDUIT OR THREADED STEEL ALL LOCAL CODES AND ORDINANCES, THE STATE OF CALIFORNIA <br /> r INTERMEDIATE METAL CONDUIT. RIGID NONMETALLIC CONDUIT COMPLY WITH ELECTR{CAL SAFETY ORDERS, THE NEC AND ANY ADDITIONAL <br /> EXISTING (2) 15,000 GALLON ART, 347 SHALL BE PERMITTED WHERE BURIED UNDER NOT LESS THAN JURISDICTIONS RELATING TO THE WORK. <br /> XERXES UNDERGROUND DOUBLE EXISTING VALVE 2 FEET BELOW GRADE EXCEPT WHERE PROHIBITED BY LOCAL CODE OR 3 ELECTRICAL CONTRACTOR SHALL- INCLUDE ALL FEES, INCLUDING <br /> WALL FIBERGLASS STORAGE TANKS AUTHORITIES HAVING JURISDICTION. <br /> 1 .. . . .. .. . . .. . . .. . . , . , . . .. . . .. .. . .. . . .. . . .. . . . .. . , . . . ' '•'•'•'•.•'•' . , �.�.�.�.-. . (10' alA:) To R1=MAIN. To REMAINCONNECTION FEES AND SERVICE CHARGES, AND SHALL FURNISH <br /> •. : . . . . . . . . . . . . , . . ... . ALL PERMITS NECESSARY FOR THE ELECTRICAL SYSTEM. <br /> 2. PVC CONDUIT SHALL BE USED FOR UNDERGROUND RUNS ONLY AS ALLOWED <br /> . . . .. . ---- -------- -- --- -___�_ �- . . . .• . . . .. .•.•.•.-. .•.-.•.-.•.-.-. . <br /> BY N.E.C. ARTICLE 347, REFER TO ARTICLE 300-5 AND TABLE 300-5 FOR 4 VERIFY EXISTING SITE CONDITIONS, SERVICE REQUIREMENTS <br /> — -- - - - -- NEW REMOTE TANK FILL MINIMUM COVER REQUIf�EMENTS, PROTECTION FROM DAMAGE, ETC.; AND EXACT LOCATIONS OF SERVICE FACILITIES BEFORE SUBMITTING BID. <br /> .;.,...:., & TRUCK VALOR RECOVERY ARTICLE 250 FOR REQUIRED EQUIPMENT GROUNDING ON UNDERGROUND 5 ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER THESE <br /> [ I 8 A-19,21�31 <br /> (TYPICAL PLACES) INSTALLATION. UNDERGROUND CONDUIT RISERS, CONDUITS ENTERING A BLDG DRAWINGS FOR EQUIPMENT LOCATION AND LAYOUT. IF <br /> +1#10 <br /> #1�' fl 7 . .;. '.1. .. ;• - . .; . AND ALL ABOVE GROUND CONDUITS SHALL BE RIGID METAL CONDUITS, <br /> 7 8 NOTIFY LARCH �CTDFORISGUIDANCE LAND RN CLARIFICATION.SHALL <br /> RELOCATED CANOPY (BY EQUILON'S — ,, 3. PROVIDE GROUND CONDUCTOR IN ALL UNDERGROUND POWER / <br /> GENERAL CONTRACTOR) I O a 1 o a LINES WHETHER NOTED ON DRAWING OR NOT, ALL SITE 6 IN THE EVENT OF A CONFLICT OR INCONSISTENCY BETWEEN <br /> : ;•;•;•:• 4,1 {SELF SERVE) `.Y:.=��—�, `"� '•; ,•:•:•. CONDUCTORS SHALL BE #10 THWN CU. FOR LENGTHS GREATER ITEMS INDICATED ON THE PLANS AND/OR SPECIFICATIONS OR <br /> ___� - m I THAN 75', 3/4 MINIMUM DIA, OR AS REQUIRED U.N.Q. WITH CODE REQUIREMENTS, THE NOTES, SPECIFICATIONS OR <br /> ::. �. <br /> a o - r CODES WHICH ESTABLISH AND PRESCRIBE THE MORE COMPLETE <br /> RELOCATED CANOPY COLUMN 1 9 _ ; ... 4. INSULATION OF CONDUCTORS IN AND UNDER GASOLINE PUMP AREA WORK OR THE HIGHER STANDARD SHALL PREVAIL. <br /> & SHROUD BY EQUILON'SI 1 ;� _ SHALL BE LISTED AND APPRQVFD FOR GASOLINE/OIL. RESISTANT TYPE. <br /> 3 „G 2#10 7 EXACT ROUTING OF ALL CONDUITS WITHIN THE EXISTING <br /> GENERAL CONTRACTOR I1 G I = � BUILDING SHALL BE DETERMINED BY THE E.C. ANY COST <br /> (TYPICAL OF 4) ��� <br /> RELOCATED "DRESSER WAYNE” MULTI ACCEPTABLE WHERE PERMITTED BY CODES.. . .. 5. PROVIDE WP COVER FOR ALL EQUIPMENT INSTALLED OUTDOOR WHETHER REQUIRED TO ROUTE CONDUITS DIFFERENTLY THAN IS SHOWN <br /> I 1� - "" NOTED ON DRAWINGS OR NOT. USE OF EXISTING CONDUITS) AND J-BOXES IS ON THESE DRAWINGS SHALL BE INCURRED BY THE E.C.. <br /> PRODUCT GASOLINE DISPENSER . . . . . <br /> _:. . .. . 8 MINIMUM CONDUIT SIZE SHALL BE 3/4" U.O.N.. PROVIDE PULL- <br /> w/ CARD READERS, BLENDERS, - f 6. ALL OUTDOOR/EXTERIOR LIGHTING AND SIGNS (PARKING 8c WIRE IN ALL CONDUIT ONLY (C,O.) RUNS. USE RGS UNDERGROUND <br /> SINGLE HOSE EACH SIDE, & VAPOR I I !~;:" . WALKWAY AREA LIGHTING TO BE CONTROLLED BY TIME CLOCK <br /> VAC NOZZLES (BY EQUILON'S . . .. . . ... .. ) AND AT DISPENSI�RS. USE RGS WHERE EXPOSED AND SUBJECT TO <br /> GENERAL CONTRACTOR) �' " �// & PHOTOCELL, SEE EXTERIOR LTG CONTROL DIAGRAM, VERIFY PHYSICAL ABUSE. USE RGS, EMT, OR FLEXIBLE CONDUIT IN <br /> (TYPICAL OF 4 DISPENSERS) ^, 1� REQUIREMENTS AND INCLUDE SUCH COST IN #31D. SEE CONTROL DIAGRAM BUILDING. USE LIQUIDTIGHT FLEX AT CONNECTION TO MOTORS. <br /> 7 �� --'� THIS SHEET, <br /> RELOCATED AIR/WATER 7 %VF <br /> 1I :" " ---� 9 ALL ELECTRICAL EQUIPMENT SHALL BE ANCHORED FOR SEISMIC <br /> REELS (TYPICAL 2 PLACES) EXPLOSION PROOF ACTION IN ANY <br /> w - <br /> . . . 7 WITHIN EACH MPD FUEL DISPENSER, INSTALL ONE (1 ) EXPLO LOADING TO RESIST A HORIZONTAL FORCE A <br /> T' <br /> (BY EQUILON'S GENERAL Q- _ _ ..- ° -- _ _ 1JUNCTION BOX FOR POWER, DATA AND SIGNAL/MONI ORING. DIRECTION USING THE FOLLOWING CRITERIA: <br /> CONTRACTOR) ( ' . ;. . , .. ; ' ' CONTRACTOR TO MAKE CONNI=CTION TO DISPENSER PUMP AND L#CHT PER FIXED EQUIPMENT ON GRADE 33% OF OPERATING WEIGHT <br /> �� F_�LI..L S . . . <br /> _ - - <br /> I o p - DISPENSER SUPPLIER AND SHELL ENGINEER REQUIREMENTS. FIXED EQUIPMENT ON STRUCTURE 50% OF OPERATING WEIGHT <br /> 8 2) 3/4" G ((1 "C DISPENSER POWER WITH& FOR FLEXIBLY MOUNTED EQUIPMENT USE 2 TIMES THE ABOVE <br /> , .. . CONDUCTO & 1RS, FW <br /> DISP LASER CONTROL/MONITORING/CARD READER WITH <br /> FOR DISPENSVALUES, SIMULTANEOUS VERTICAL FORCE USE 1/3 TIMES <br /> CONTROL WIRES) TO POWER CENTER GUTTER, VERIFY ALL REQUIREMENTS HORIZONTAL FORCE, THIS CRITERIA APPLIES TO EQUIPMENT ON <br /> INCLUDING NUMBER OF WIRES. THE FLOOR, WALL, OR ROOF WITH AN OPERATING WEIGHT OF <br /> •' ' � �- __,_., ....� .-___ .-_., — �.. --- ' . . . . LESS THAN 1 ,000 LB.. <br /> . . , .. . , _�• . . 9 EXPLOSION PROOF J-80X FOR POWER CONNECTION TO DISPENSER TOP 10 THE E.C. SHALL BE RESPONSIBLE FOR VERIFYING PHYSICAL <br /> SPANDREL, VERkFY LOCATION. DIMENSIONS OF ALL EQUIPMENT FOR INSTALLATION__._ _._ - .. . . . . . . <br /> AND SHALL NOTIFY ARCHITECT/ENGINEER SHOULD ANY <br /> 10 EXISTING CONDUITS AND CONDUCTORS FOR CANOPY LIGHTS, LIGHT WELL LTS DISCREPANCY EXIST, <br /> . . .. .. ... <br /> SHELL WORDMARKS, SHELL PECTENS TO REMAIN. TYPICAL 11 COORDINATE EXACT LOCATION FOR P.O.S. EQUIPMENT AND <br /> RELOCATED SPANDREL FIELD VERIFY EXACT CIRCUIT NUMBER AND CIRCUIT ROUTING, PROVIDE ALL REQUIREMENTS FOR NEW DISPENSERS INSTALLED. <br /> (BY EQUILON'S 12 ELECTRICAL EQUIPMENT AND MATERIALS ARE TO BE LISTED AND <br /> GENERAL CONTRACTOR) 11 . REUSE EXISTING CONDUITS WHERE APPLICABLE, IN GOOD CONDITION, LABELED BY UL, AND INSTALLED PER THEIR GUIDELINES. <br /> (TYPICAL OF 2) PERMITTED BY CODE AND CITY INSPECTOR, <br /> 13 ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CORING, <br /> ( J-BO12 <br /> X ON NEW COLUMN WITH REQUIRED CONDUIT AND CONDUCTORS TO CUTTING, PATCHING AND REFINISHING OF WALLS AND SURFACES <br /> D <br /> EXISTING CIRCUIT(A-18,20,22,24,19,21 ,23,25,27,29,31) SEE SHEET E-2 WHENEVER IT IS NECESSARY FOR PENETRATION, ALL OPENINGS <br /> FOR CONTINUATION. MADE SHALL BE SEALED TO MEET THE FIRM RATING AND <br /> STRUCTURAL INTEGRITY OF THE PARTICULAR WALL, FLOOR, OR <br /> TANKS AND DI PEN ERS PLAN CEILING. <br /> 14 ALL ELECTRICAL FIXTURES AND EQUIPMENT SHALL BE GROUNDED. <br /> SCALE 1 „ 10' <br /> - 0" <br /> ALL CONVENIENCE RECEPTACLES SHALL BE GROUNDING TYPE. <br /> 15 MINIMUM WIRE SIZE TO BE #12 AWG. THWN. EXCEPT CONTROL <br /> WIRING WHICH SHALL BE #18 THWN, <br /> 16 ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL <br /> ELECTRICAL WIRING CONDUITS, WIREMOLDS, FITTINGS, LIGHTING <br /> TRACKS, RECEPTACLES, AND SWITCHES REQUIRED FOR EQUIPMENT <br /> AND FIXTURES FURNISHED, THE GENERAL CONTRACTOR SHALL <br /> FURNISH AND INSTALL ALL OTHER ELECTRICAL REQUIREMENTS TO <br /> COMPLETE INSTALLATION, AND LEAVE READY FOR OPERATION. <br /> 17 ELECTRICAL CONTRACTOR SHALL FURNISH TEMPORARY CONSTRUCTION <br /> POWER WHERE REQUIRED. <br /> EXTERIOR LTG. CONTROL DIAD. <br /> NOTE: ALL NEW AND EXISTING OUTDOOR LIGHTING AND SIGNS <br /> EXISTING INTERNALLY ILLUMINATED <br /> SHELL PECTEN (TTP. 2} TO BE CONTROLLED BY TIME CLOCK & PHOTOCELL(INSTALL <br /> ON ROOF FACING NORTH AVOID SHADED AREA) ,VERIFY <br /> REQUIREMENTS. INCLUDE ALL COST IN BID, <br /> 18 120V H N <br /> 2 3 23 23 RSG CONDUIT, SIZE AS NOTED DEDICATED CIRCUIT <br /> 24 _0117= -- (, 22 �P PHOTO CELL <br /> 12 1 K I <br /> 11 - SEAL FITTING, WHERE <br /> 20 o a -- -..__.. "___ ° ... Q II 18 REQUIRED AND SPECIFIED <br /> I! - "ON—OFF" <br /> II <br /> L <br /> {(SE[_l- SE,4vF} r FINISHED GRADEOVERRIDE ,24HR 7-DAY <br /> O a ' ° EXISTING CANOPY LTS TO OR FLOOR LEGEND SWITCH IN - -•�--.. S TC TIME CLOCK <br /> RELOCATED CANOPY EQUILON'S - REMAIN (TYP. 12) __ CASHIER AREA �- -�-- — <br /> ( I� UNDERGROUND CONDUIT RUN <br /> GENERAL CONTRACTOR) 25 25 2 <br /> I� 7 r. � -----RSG CONDUIT BEND OR ELBOW <br /> ELECTRICAL SITE NOTES NUMBER <br /> C <br /> EXISTING LIGTYP.) . LIGHTS 08 <br /> � COUPLING, METALLIC I <br /> I TO REMAIN (TTP.) — <br /> 10 TYP GALVANIZED STEEL p JUNCTION BOX TYPE AS NOTED <br /> I 27 27 29177 1.1NON-METALLIC CONDUIT (RIGID PVC) I � <br /> { "— L� I <br /> SIZE AS SHOWN ON SCHEDULE <br /> KLAL05W <br /> S1 , DIVISION 1 AREA E--------� - TO ALL EXTERIOR <br /> GRADE & DISP, HOUSINGS}EXISTING INTERNALLY ILLUMINATED TO PANEL LIGHTS AND SIGNS <br /> SS 1 , DIVISION 2 AREA (SEE PLAN) > <br /> SHELL WORgMARK (TTP, 2) ....,.. (ABOVE GRADE) <br /> I a Q <br /> P TYPICAL. OONDUIT STUB-UP DETAIL.`_ FULLLVI�ER �ra _. <br /> II <br /> — - --jE•----- X INDICATES CONDUIT SEAL I <br /> a a o a NOT TO SCALL= �T I I LTG CONTACTOR(S) WITH <br /> REQUIRED NUMBER <br /> L OF CONTACTS <br /> 24 31 31 _ 29 ( 22 <br /> r -i <br /> �( 0 a L APPR YID <br /> DRAWING ISSUED FOR DATE A&S SHELL REVISIONS SHELL OIL COMPANY. <br /> 0CEDURESHELL ENGINEER NO. I7ATt BY �r COMMENTS _ <br /> 20 _ __-- _ _ ___,� — __ -� -_ - -- -. HOUSTON, TEXAS <br /> ENGINEERb INC . SMEL FABRIC4TOr7 <br /> NAME------------ -- <br /> DETAILS <br /> MECHANICAL ELECTRICAL PLUMBING ENERGY PLANNING <br /> 7%=715550-8 ROCKFIELD BLVD., #220 TEL: (949) 837-3133 <br /> CANOPY PLAN IRVINE, CA, 926118 FAX: (949) 837-9568 pERMIr PLANS PREPARED BY., 3011 W. BENJAMIN HOLT DR. & FREEWAY OFF-RAMP <br /> D 5 10 15 -- _ <br /> SCALE : I " = 10' — 0" ID CONTRACT DOCUMENT -' STOCKTON, CALIFORNIA <br /> These drawings, specifications, calculations, designs & arrangements are and BNOT FOR CONSTRUCTION A $ ENGINEERING�� <br /> _ <br /> GRAPHIC SCALE shall remain the sole property of PROCEDURE ENGINEERS INC,. All rights are PLANNING ENGINEERING CONSTRUCTION MANAGEMENT SCALE; AS NOTED <br /> D coNsrRucrlON WIC #2D4-7524-4404 <br /> reserved for specific project that these plans are prepared for, Duplication DO NOT USE FOR CONST '""°"�"" 1243 ALPINE ROAD, SUITE 109 <br /> of any kind for any purpose without any expressed written permission of UNLESS BOTH SIG. ARE IN HAND DATE: 10 20 99 <br /> .�.. WI�LNUT CREEK, CALIFORNIA 94596 <br /> PROCEDURE ENGINEERS INC. prohibited. RECORD arlAwlNG PHONE: 925-933057$ FAX: 925.933-0588 DWN. BY: M.L.C. DRAWING E-3 <br /> CHKD. BY:H.A. PEI 9034 SHEET OF <br />