Laserfiche WebLink
D• At construction for new underground storage tanks containing motor vehicles fuel [Section 2633]. <br /> (, (1) Monitoring and response plan [Section 26341. <br /> (2) Underground storage tank composed of.... <br /> ,I,v1 (a) Fiberglass reinforced plastic. <br /> Iv (b) Cathodically protected steel. <br /> (c) Steel clad with fiberglass reinforced plastic. <br /> (d) Other material that complies with section 2631 and 2632. <br /> (3) Floor of Leak interception and detection system constructed on a firm base and sloped to a <br /> collection sump (use of membrane liners comply with section 2631 (d) (6) requirements.) <br /> (4) Access casings installed in the collection sump of the secondary containment system with <br /> ,IJ(� backfill in the interstitial space. The access casing shall meet all of the following: <br /> rv�n Designed and installed to allow the liquid to flow into the casing. <br /> Sized to allow removal of collected liquid and able to withstand all anticipated applied <br /> �( stresses. <br /> M Constructed of material that will not be structurally weakened. <br /> Screened along entire vertical zone of permeable material. <br /> Capable of preventing leakage of any hazardous substance from the casing. <br /> Extend to the ground surface and covered with a locked waterproof cap. <br /> Capable of meeting S.J. Co. PHS-EHD Nell Standards. <br /> Leak interception and detection system shall prevent the leaked hazardous substance from <br /> entering ground water. <br /> 14. INTERSTITIAL SPACE MONITORING 7-ftm:a No MpN(TD21n SVS-nMfFR� �cIS`17N� � 'IPoN, <br /> A. visual monitoring [Section 2632 (c) (1)] <br /> Iv (a) Exterior surface and floor beneath tank monitored by direct viewing <br /> (b) Daily visual inspections <br /> OVA— (c) Liquid level in tank to be recorded at time of inspection <br /> OAN (d) If liquid observed around or beneath primary tank, owner will determine if an unauthorized release <br /> has occurred. <br /> 8. Mechanical or electronic monitoring [Section 2632 (c) (2)] <br /> (a) Continuous monitoring system connected to an audible and visual alarm system. <br /> Monitoring equipment to be installed <br /> Manufacturer: A 4 <br /> Model Number: 4- L J—3 y� <br /> �`-'�• I' lIN Sensor Type: Vapor Liquid X Roth. <br /> Sensor/Panel specifications. <br /> Location(s) for sensors: <br /> Tank:JNjMt;T1T9AL Piping: PI PI r SW <br /> Dispenser:CONIPt1fJ(�Qt�i �b)( <br /> C. Monitoring and response plan submitted [Section 2632 (d) (1) 6 (2)]. <br /> is. Any special accessories, fittings, coatings, or Linings not inherent within the initial design of the 10 tank or <br /> double-wall UST. [Section 2631 (b)] <br /> A. Approved by a nationally recognized independent testing organization. <br /> S. Demonstration of integrity with the primary and/or secondary containment. <br /> 6 <br />