My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2802
>
2300 - Underground Storage Tank Program
>
PR0516736
>
COMPLIANCE INFO_2015 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:24 AM
Creation date
11/8/2018 10:25:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2018
RECORD_ID
PR0516736
PE
2361
FACILITY_ID
FA0012764
FACILITY_NAME
SAFEWAY FUEL CENTER #1769
STREET_NUMBER
2802
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2802 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\C\COUNTRY CLUB\2802\PR0516736\COMPLIANCE INFO MARCH 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO MARCH 2016 - PRESENT
QuestysRecordDate
1/18/2018 5:13:03 PM
QuestysRecordID
3117835
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
332
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County 1"0 <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209)468-3433 Web:www.sigov.org/ehd <br /> . Utz ` <br /> r x'fe Ur1 : "_,... ;�:.- -.. is .,a.. ,. .,, ,.,ri.. `:-.., mxe „�.r w,... :er. w <br /> Facility Name: Facility Address: Date: <br /> Safeway Fuel Center#1769 Stockton o-qc S COuYin' January 20, 2015 <br /> � ��` axa k°, t h e H z d ro"u ' �mi4`�= ' [ �` 4h+ �4 °� ' <br /> , <br /> ' ka_ °*, „e orM once to,Coni'I' <br /> Item# Remarks <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm. <br /> The 89 Fill sump sensor failed to activate an audible and visual alarm when tested to ensure continuous monitoring of <br /> the tank system. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow <br /> of product at the dispenser when it detects a leak. The sensor was replaced and retested during the inspection. A <br /> "UST Retrofit Verification with Inspector Already Onsite"form has been completed and provided to the operator and <br /> contractor. <br /> 310 CCR 2636(f)(1) Sensor in a turbine sump failed to activate an audible and visual alarm or stop the flow product. <br /> The 87 STP sump sensor failed to activate an audible and visual alarm when tested to ensure continuous monitoring of <br /> the tank system. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow <br /> of product at the dispenser when it detects a leak. The sensor was shaken and retested during the inspection. This is <br /> a repeat violation, Class II. This was corrected on site. <br /> Overall Inspection Comments: <br /> Violation checklist left with Sandra Harbaugh on January 20, 2015. Complete inspection report mailed on January <br /> 21, 2015. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by February 19, 2015 . <br /> Consent to perform the inspection, take photos and collect samples was given by Sandra Harbaugh, Fuel <br /> Manager. This facility's designated operator is Maria Guarnelli (ICC expiration date: 04/17/2016 ) . The service <br /> technician was Kristopher Bell (ICC expiration date: 09/11/2016 ), who had the following manufacturer's <br /> certifications: VMI 11/18/2016; Veeder Root 03/04/2016 . <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Owner/Operator: Written Agreement (if <br /> applicable), UST Letter from Chief Financial Officer, and Owner Statement of Designated UST Operator <br /> Compliance. <br /> Note: The wiring 89/91 annular sensor was observed with two splices outside the electrical box. The technician <br /> rewired the sensor at the time of inspection. No permit is required for this repair. <br /> Provided: Return to Compliance Certification Form <br /> Received by(initial): Inspector: ��y Phone: Date: <br /> STACY RIVERA, Senior REHS lJ7 (209) 468-3440 01/20/2015 <br /> Page 4 of 5 <br />