Laserfiche WebLink
,11we San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sioov.org/ehd <br /> Underground Storage Tank Program Inspecti epo <br /> Facility Name: Facility Address: � �JJ Date: <br /> Safeway Fuel Center#1769 Stockton 2800 ICALe+1 el t-clb RwA• January 20, 2015 <br /> _ UST System O <br /> 322 CCR 2636(f)(2) Line leak detector not installed n V ❑R ❑COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi ❑V a R ❑COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty o V o R c COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons o V ❑R ❑COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present,was overridden,or failed to meet overfill requirements c V ,R n COS <br /> 327 HSC 25283.5 Unburied below grade UST failed to meet exemption status o V o R ❑COS <br /> 328 CCR 2717.1(g) Tampered with red tag ❑V ❑R o COS <br /> 329 CCR 2717.1(f) Deposited petroleum into a red tagged UST o V o R o COS <br /> 330 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 331 CCR 2631.1 UST system not compatible with the substance stored o V o R ❑COS <br /> 332 HSC 25298(b) Failed to comply with temporary closure requirements o V o R o COS <br /> 333 HSC 25298(c) Failed to comply with permanent closure requirements ❑V o R ❑COS <br /> Non-Press. Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve V ,R o COS <br /> 402 CCR 2643(4) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R in COS <br /> ­dffierviolations <br /> 2010 See below Unlisted Administration/Documentation violation o V ❑R o COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V in R in COS <br /> 2060 See below Unlisted Design/Construction violation c V n R ❑COS <br /> SUMMARY OF VIOLATI <br /> (CLASS I,CLASS ll,or MINOR-Notice to Comply):. <br /> Item# Remarks <br /> 207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to document Q4 91 Electronic Line Leak Detector alarms on the designated operator <br /> monthly inspection reports and failed to check that they were responded to appropriately. The Q4 alarms were not <br /> printed on the alarm histories attached to the designated operator monthly inspection reports. During the monthly <br /> inspection, the designated operator shall review the alarm history for the previous month, check that each alarm was <br /> documented and responded to appropriately, and attach a copy of the alarm history with documentation taken in <br /> response to any alarms to the monthly report. Ensure that designated operators performing monthly inspections at this <br /> facility are including all of the required information on the reports. This is a repeat violation, Class ll. <br /> Received by(initial): Inspector: Phone: Date: <br /> AAal d. STACY RIVERA, Senior REHS (209)468-3440 01/20/2015 <br /> Page 3 of 5 <br />