My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2802
>
2300 - Underground Storage Tank Program
>
PR0516736
>
COMPLIANCE INFO_2015 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:24 AM
Creation date
11/8/2018 10:25:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2018
RECORD_ID
PR0516736
PE
2361
FACILITY_ID
FA0012764
FACILITY_NAME
SAFEWAY FUEL CENTER #1769
STREET_NUMBER
2802
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2802 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\C\COUNTRY CLUB\2802\PR0516736\COMPLIANCE INFO MARCH 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO MARCH 2016 - PRESENT
QuestysRecordDate
1/18/2018 5:13:03 PM
QuestysRecordID
3117835
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
332
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,11we San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sioov.org/ehd <br /> Underground Storage Tank Program Inspecti epo <br /> Facility Name: Facility Address: � �JJ Date: <br /> Safeway Fuel Center#1769 Stockton 2800 ICALe+1 el t-clb RwA• January 20, 2015 <br /> _ UST System O <br /> 322 CCR 2636(f)(2) Line leak detector not installed n V ❑R ❑COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi ❑V a R ❑COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty o V o R c COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons o V ❑R ❑COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present,was overridden,or failed to meet overfill requirements c V ,R n COS <br /> 327 HSC 25283.5 Unburied below grade UST failed to meet exemption status o V o R ❑COS <br /> 328 CCR 2717.1(g) Tampered with red tag ❑V ❑R o COS <br /> 329 CCR 2717.1(f) Deposited petroleum into a red tagged UST o V o R o COS <br /> 330 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 331 CCR 2631.1 UST system not compatible with the substance stored o V o R ❑COS <br /> 332 HSC 25298(b) Failed to comply with temporary closure requirements o V o R o COS <br /> 333 HSC 25298(c) Failed to comply with permanent closure requirements ❑V o R ❑COS <br /> Non-Press. Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve V ,R o COS <br /> 402 CCR 2643(4) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R in COS <br /> dffierviolations <br /> 2010 See below Unlisted Administration/Documentation violation o V ❑R o COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V in R in COS <br /> 2060 See below Unlisted Design/Construction violation c V n R ❑COS <br /> SUMMARY OF VIOLATI <br /> (CLASS I,CLASS ll,or MINOR-Notice to Comply):. <br /> Item# Remarks <br /> 207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to document Q4 91 Electronic Line Leak Detector alarms on the designated operator <br /> monthly inspection reports and failed to check that they were responded to appropriately. The Q4 alarms were not <br /> printed on the alarm histories attached to the designated operator monthly inspection reports. During the monthly <br /> inspection, the designated operator shall review the alarm history for the previous month, check that each alarm was <br /> documented and responded to appropriately, and attach a copy of the alarm history with documentation taken in <br /> response to any alarms to the monthly report. Ensure that designated operators performing monthly inspections at this <br /> facility are including all of the required information on the reports. This is a repeat violation, Class ll. <br /> Received by(initial): Inspector: Phone: Date: <br /> AAal d. STACY RIVERA, Senior REHS (209)468-3440 01/20/2015 <br /> Page 3 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.