My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ESCALON
>
1329
>
2300 - Underground Storage Tank Program
>
PR0231487
>
INSTALL_2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2023 4:32:34 PM
Creation date
11/8/2018 10:25:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2017
RECORD_ID
PR0231487
PE
2351
FACILITY_ID
FA0000293
FACILITY_NAME
Pershing Holdings, Inc. DBA Esclon Arco
STREET_NUMBER
1329
STREET_NAME
ESCALON
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22510003
CURRENT_STATUS
01
SITE_LOCATION
1329 Escalon Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\E\ESCALON\1329\PR0231487\2017 INSTALL.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
445
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Time In: <br /> Time Out: <br /> �oaa . �o San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue , Stockton , CA95205- 6232 <br /> Telephone: (209) 468-3420 Fax : (209 ) 464-0138 Web: www. sjgov . org/ehd <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: ARCO AM PM Date : 02/01 /2018 <br /> Address : 1329 ESCALON AVE , ESCALON 95320 <br /> Requestor: PAUL RAJ , CHADHA CONSTRUCTION Telephone: (209) 595-0787 <br /> Program Element : 2303 - UST/PIPING INSTALLATION Request #: SR0074800 <br /> Inspection Type: 131 - UST INSTALLATION INSPECTION <br /> Onsite Service Technician: ICC Service Tech/lnstaller Exp , Date : <br /> Manufacturer training : <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> Witnessed the following : <br /> - Functionality of all vacuum and liquid " smart' sensors. <br /> -Verification of proper brine reservoir location in all UDCs. <br /> -Verification of proper brine levels in all UDCs. <br /> -Verification of proper identification of all sensors. Sensors were not yet placed in their final positions at the time of inspection . <br /> Most sensors were pulled out of the sumps to allow the technicians access into and out of the sumps . <br /> -Visual verification of unaltered shroud boots on all spill containers. <br /> -Verification of drop tube measurements to ensure 95 % tank volume shut off. No change in measurements was noted . <br /> -Verification of brine communication in the 87 and 91 fill sumps . <br /> -Visual inspection of the alterations for raising of the shear valves in the UDCs . <br /> -Verification of methods for vacuum fitting repair/replacement . <br /> -Visual verification of adhesive removal from the repaired vacuum fitting in the 87 fill sump . <br /> -Verification of resin on the grout in the UDCs , as requested by Western Fiberglass. <br /> Still needed : <br /> - Photos taken before and after UDC repairs , as requested by Western Fiberglass . <br /> -Verification of vacuum communication in all piping at every termination point The vacuum communication could only be <br /> verified at dispenser 11 /12 and the vent sump . No additional termination points were tested . <br /> -Primary piping line testing of the 87 and 91 product lines . Piping was disconnected and additional portions were added below <br /> the shear valve in the UDCs . <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code. If a reinspection is required , fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Byron Molina , Technician <br /> EH Specialist : STACY RIVERA Phone : ( 209) 468 -3440 <br /> FA0000293 SR0074800 SC131 02/01 /2018 <br /> EHD 23-01 Rev, 06/30/15 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.