My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0079782
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ALLEN
>
19155
>
4200/4300 - Liquid Waste/Water Well Permits
>
SR0079782
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2018 3:04:18 PM
Creation date
11/29/2018 2:51:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
SR0079782
PE
4201
STREET_NUMBER
19155
Direction
E
STREET_NAME
ALLEN
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24507081
ENTERED_DATE
10/25/2018 12:00:00 AM
SITE_LOCATION
19155 E ALLEN RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
DAfonskaia
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L BIG = KINETIC ' <br /> SERVICE PRO° CONTROL CENTER <br /> The Service Pro electrical control center with MCD technology <br /> MODEL TNT AUXILIARY INPUT <br /> shall provide Monitoring, Compliance and Diagnostic functions NAMEPLATE O O LABEL PAD <br /> for the Singulair treatment plant using a microprocessor based ERVICE PRO" <br /> platform. The Service Pro control center shall contain nonvolatile POWER ONTROL CENTER AUXILIARY 1 <br /> memory to prevent loss of programming in the event of a power LIGHT "" I ---LIGHT <br /> TNT <br /> failure. The pre-wired controls shall be mounted in a lockable "E°"" <br /> NEMA rated enclosure designed specifically for outdoor use. Each ALARM . ."„ AUXILIARY INPUT <br /> LIGHT LABEL PAD <br /> Service Pro control center shall be a UL listed assembly and <br /> shall include a factory-programmed timer,alarm light,reset button, PHONE AUXILIARY 2 <br /> power switch, power light, phone light, aerator alarm light and LIGHT LIGHT <br /> three auxiliary alarm lights. The control center shall monitor all <br /> treatment system operating conditions including aerator over AERATOR AUXILIARY INPUT <br /> current,aerator under current and open motor circuit. In the event LIGHT ^ °°°^ °°° LABEL PAD <br /> O M10^.SERVICEPROMCD.COM <br /> the control center detects one of these conditions, power to the <br /> aerator shall be interrupted, a diagnostic sequence shall be In RESET AUXILIARY 3 <br /> P 9 q g BUTTON ON LIGHT <br /> and the visual alarm shall activate. After a programmed recovery °Rwece,INC. <br /> AM <br /> interval,an automatic restart attempt shall be initiated. If normal CONTROL CENTER NOR U SAOHIO POWER <br /> aerator operation does not resume during 24 programmed recovery INSERT OFF SWITCH <br /> and restart cycles, the audible alarm shall activate and the <br /> telemetry system shall report the specific condition to the Service Pro monitoring center. In the event that any of the auxiliary <br /> inputs detect abnormal operation of the treatment system auxiliary equipment,the audible and visual alarms shall immediately <br /> activate and the telemetry system shall report the alarm condition to the monitoring center. The service provider shall automatically <br /> be notified by the Service Pro monitoring center of the specific alarm condition using phone,fax or email. <br /> AERATOR TIME CYCLE <br /> A factory-programmed timer built into the Service Pro control center shall provide a total of twelve hours of aerator operation per <br /> day. The non-adjustable timer shall create a 60 minute aeration cycle followed by a 60 minute anoxic cycle during which the <br /> aerator shall be off. Use of an aerator timer can seriously affect system performance and operating cost. Systems that have not <br /> been performance certified, at a timed aeration cycle, by an <br /> independent ANSI accredited testing laboratory shall not be <br /> ' considered for this application. <br /> SERVICE PRO® MONITORING CENTER <br /> s ld,ww+uCk,iM. �� .rfI1f IIIW If WA <br /> ••ew'Mn nlhvlWOr Ir <br /> ^• •»°°»^ t%.5—k• The Service Pro monitoring center shall include a 128 bit encrypted <br /> r., :,. ..nY•^•r„ dtowd b.041Y YfY aCCHf In - <br /> "'""'""" """Y <br /> 1password protected website for interface with the monitoring center <br /> IIb001Y f <br /> Q&.# <br /> g1-1.41:I.wY M IN <br /> p••�,: •• w[c.ui i.t"rY14M�«f—w.. .y <br /> • database. Access to the secure website shall be obtained through <br /> ,new ""e"""° '°""'t" a unique user name and password that provides tiered access to <br /> ou renx"noon (n.w no IF.'Ndy'tw <br /> data from monitored treatment systems. Access level tiers shall <br /> r... r,srr lt" Itm.ave.)WI<N1c VY.fNenw <br /> J11111111100"' <br /> c" <br /> a U. s<rYl�eNo include distributors, service providers regulatory agencies and <br /> I,..tceY-C.a U. <br /> ;.,,,,...,., r-.,r.• centro)center <br /> individual system owners. Distributors and service providers shall <br /> N. °°°'" be able to create accounts, maintain service records and grant <br /> 5"• n menal ume,. <br /> d"hoa regulatory agencies access to the information. Individual system <br /> owners shall be able to view information regarding their own <br /> wastewater treatment systems, as well as download and print <br /> instructional information. Integrity of stored data shall be <br /> maintained through the use of multiple servers operating in <br /> www.servicepromcd.com geographically isolated locations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.