1331
>
2300 - Underground Storage Tank Program
>
PR0231332
>
COMPLIANCE INFO 2002 - 2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2019 2:07:54 PM
Creation date
12/4/2018 11:32:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2005
RECORD_ID
PR0231332
PE
2361
FACILITY_ID
FA0003961
FACILITY_NAME
LODI MUNI SERVICE CENTER
STREET_NUMBER
1331
Direction
S
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95240
APN
03104050
CURRENT_STATUS
01
SITE_LOCATION
1331 S HAM LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 4. TANK ANNULAR TES 'G- � <br /> Test Method Developed By: LE Tank Manufacturer r dustry Standard Professional Engineer <br /> ✓i Other(Specify) <br /> Test Method Used: ❑Pressure &Vacuum Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used: Equipment Resolution: <br /> "`7 <br /> Tank# Tank# Tank# r Tank# <br /> Is Tank Exempt From Testing- Yes o -7 Yes G No i�Yes No C Yes C No <br /> Tank Capacity: i <br /> Tank Material: <br /> Tank Manufacturer. / t <br /> Product Stored: <br /> Wait time between applying <br /> pressure/vacuum/water and , <br /> starting test: ! �� <br /> Test Start Time: <br /> Iiritial Reading(Rj): i <br /> Test End Time: _7 G <br /> Final Reading(RF): '�..jo <br /> Test Duration: ;i I/ <br /> Change in Reading(RF-R4): <br /> Pass/Fad Threshold or Criteria: ✓� /� <br /> Pass C! .aiU. Pass Cj;l ail 1 Pass., 0 Favi I Q-.-Pass Q-:Fail <br /> Was sensor removed for testing? Ps 01 No ❑NAI ❑Yes 0 No NA Yes ❑No _NA j ❑Yes C No [I NA <br /> Was sensor properly replaced and As 5 No -1 NA ( G Yes 0 No ❑NA Yes ❑No '7'NA n Yes ❑No ❑NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up far failed tests) <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic <br />
The URL can be used to link to this page
Your browser does not support the video tag.