My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAM
>
1331
>
2300 - Underground Storage Tank Program
>
PR0231332
>
COMPLIANCE INFO 2002 - 2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2019 2:07:54 PM
Creation date
12/4/2018 11:32:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2005
RECORD_ID
PR0231332
PE
2361
FACILITY_ID
FA0003961
FACILITY_NAME
LODI MUNI SERVICE CENTER
STREET_NUMBER
1331
Direction
S
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95240
APN
03104050
CURRENT_STATUS
01
SITE_LOCATION
1331 S HAM LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> SWRCB, January-2002 Page.of <br /> 4. T-kNKAINNULAR TESTLNG <br /> Test Method Developed By: E Tanic Manufacturer I Industry Standard Professional Engineer <br /> 0 Other(Specify) <br /> Test Method Used: E Pressure - Vacuum Hydrostatic <br /> 0 Other(Specify) <br /> Test Equipment Used: Equipment Resolution: <br /> Tank# Tank# Tank# Tank# <br /> Is Tank Exempt From Testing?' E Yes No 11 Yes E,NO j Yes No Yes No <br /> Tank Capacity: <br /> Tank Material: <br /> Tank Manufacturer: <br /> Product Stored: <br /> Wait time between applying <br /> pressureivacuum/water and <br /> starting test: <br /> Test Start Time: <br /> Initial Reading(IRq): <br /> Test End Time: <br /> Final Reading <br /> (RF): <br /> Test Duration: <br /> Change in Reading(Rt-Rt): <br /> Pass/Fail Threshold or Criteria: <br /> Test R 0:.Pass. Fait: 0- Pass 0.Fail 0� Pass 0 Fad" 11 Pass 0 Fait. <br /> Was sensor removed for testing?— E Yes 0 No NA :]Yes E-No ---NA OYes CI-No ONA F-Yes ]Nio NA <br /> Was sensor property replaced and NA Yes <br /> ,Yes El No No :1 NA 1:1 Yes E No CNA 0 Yes -NA <br /> verified functional after testing'? I I <br /> Comments-(include information on repairs made prior to testing, and recommended follow-apfor failed tests) <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic <br />
The URL can be used to link to this page
Your browser does not support the video tag.