My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAM
>
1331
>
2300 - Underground Storage Tank Program
>
PR0231332
>
COMPLIANCE INFO 2002 - 2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2019 2:07:54 PM
Creation date
12/4/2018 11:32:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2005
RECORD_ID
PR0231332
PE
2361
FACILITY_ID
FA0003961
FACILITY_NAME
LODI MUNI SERVICE CENTER
STREET_NUMBER
1331
Direction
S
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95240
APN
03104050
CURRENT_STATUS
01
SITE_LOCATION
1331 S HAM LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page of <br /> 4. TANK ANNULAR TES <br /> Test Method Developed By. ❑Tank Manufacturer k6dustry Standard ❑Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ❑Pressure k<cuum ❑Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Equipment Resolution: <br /> Film <br /> r 4 orx_r,n� ;e� Tank# Tank# Tank# "j Tank# <br /> Is Tank Exempt From Testing?' ❑Yes o ❑Yes o ❑Yes V<o ❑Yes G o <br /> Tank Capacity: <br /> Tank Material: s <br /> Tank Manufacturer: U <br /> Product Stored: (�/1i� p `✓� L <br /> Wait time between applying <br /> pressure/vacuum/water and _ <br /> starting test: %o <br /> Test Start Time: Le) �I" g a v <br /> Initial Reading(RI): �/y ,�fj l <br /> Test End Time: : �7 <br /> Final Reading(RF): <br /> Test Duration: A7 <br /> Change in Reading(RF-R& O f ) O <br /> Pass/Fail Threshold or Criteria: / /'� ��p �+ yD �e5� <br /> T :BesuIt± bass. CI Fast;: Pass © aiF s: ❑fail ass 13'_Fag <br /> Was sensor removed for testing? es ❑No ❑NA es No ❑NA "es No ❑NA es No ❑NA <br /> Was sensor properly replaced and es ❑No 11 NA es ❑No 11 NA es ❑No ❑NA es ❑No P,NA <br /> verified functional after testin ? <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> I Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic <br />
The URL can be used to link to this page
Your browser does not support the video tag.