Laserfiche WebLink
F. In -Tank Gauging I SIR Equipment: ® Check this box if tank gauging is used only for inventory control. <br />❑ Check this box if no tank gauging or SIR equipment is installed. <br />This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. <br />Complete the following checklist: <br />® Yes <br />❑ <br />No' <br />Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br />® Yes <br />❑ <br />No` <br />Were all tank gauging probes visually inspected for damage and residue buildup? <br />® Yes <br />❑ <br />No' <br />Was accuracy of system product level readings tested? <br />® Yes <br />❑ <br />No' <br />Was accuracy of system water level readings tested? <br />;_m_ <br />® Yes <br />❑ <br />No` <br />Were all probes reinstalled properly? <br />❑ Yes ® No* Were all items on the equipment manufacturer's maintenance checklist completed? <br />` In Section H. below. describe haw and whop th— d.fi se. i..... . .. — <br />Line Leak Detectors (LLD): ❑ Check this box if LLDs are not installed. <br />Complete the following checklist- <br />® Yes <br />❑ No' <br />For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check all that apply) <br />ElN/A <br />Simulated leak rate: ® 3 g.p.h.; ❑ 0.1 g.p.h ; ❑ 0.2 g.p.h. <br />® Yes <br />❑ No' <br />Were all LLDs confirmed operational and accurate within regulatory requirements? <br />® Yes <br />❑ No' <br />Was the testing apparatus properly calibrated? <br />® Yes <br />❑ No' <br />For mechanical LLDs, does the LLD restrict product flow If it detects a leak? <br />❑ N/A <br />❑ Yes <br />❑ No' <br />For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? <br />® N/A <br />❑ Yes <br />❑ No" <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? <br />® N/A <br />❑ Yes <br />❑ No' <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? <br />® N/A <br />❑ Yes <br />❑ No' <br />For electronic LLDs, have all accessible wiring connections been visually inspected? <br />® N/A <br />Ve <br />n <br />iI — -- I ­'--""----- .........,..,r.,,.,,,,,,,o,,-.--,,,a,"o„aw.cnccRnstcumpieceur <br />In Section H, below, describe how and when these deficiencies were or will be corrected. 11 <br />H. Comments: <br />DSL 120 3 26 22 PASS <br />87 110 3 28 15 PASS <br />Monitoring System Certification Page 3 of 4 2/21/07 <br />