My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1894
>
1600 - Food Program
>
PR0521425
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:30 AM
Creation date
12/7/2018 3:31:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0521425
PE
1614
FACILITY_ID
FA0014519
FACILITY_NAME
PAPA MURPHYS TRACY
STREET_NUMBER
1894
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402004
CURRENT_STATUS
01
SITE_LOCATION
1894 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
JCastaneda
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\1894\PR0521425\COMPLIANCE PRE 2016.PDF
QuestysFileName
COMPLIANCE PRE 2016
QuestysRecordDate
5/25/2016 8:11:21 PM
QuestysRecordID
3093627
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
to Smith® Commercial Electric Water Heater <br /> 2 <br /> RECOVERY RATE IN GALLONS ER HOUR AT TEMPERATURE RISE OF <br /> O Standard BTU/ 30°F 40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F <br /> Fr WATERouiLET kW In ut Hour 17°C 22°C 28°C 33°C 39°C 45°C 50°C 56°C 61°C 67°C 72°C 78°C _ <br /> 6 20,478 82 62 49 41 35 31 27 25 22 21 19 18 <br /> o Q 00 310 233 166 155 133 116 103 93 85 78 72 66 <br /> 9 30,717 123 92 74 62 53 46 41 37 34 31 28 26 <br /> 465 349 279 233 199 174 155 140 127 116 107 100 <br /> L ca+ounovenn+c 12 40,956 164 123 98 8 70 61 55 49 45 41 38 35 <br /> 620 465 372 266 233 207 186 169 155 143 133 <br /> 0 13.5 46,075 184 138 111 2 79 69 62 55 50 46 43 40 <br /> .1_/s L 698 523 419 299 262 233 209 190 174 161 150 <br /> U&If• 15 51,195 205 154 123 102 88 77 68 61 56 51 47 44 <br /> N/�ISN� 775 582 465 3 332 291 258 233 211 194 149 166 <br /> W Net OPENING 18 61,434 246 184 148 123 105 92 82 74 67 62 57 53 <br /> 930 698 558 465 399 349 310 279 254 233 215 199 <br /> ® 24 81,912 328 197 164 140 123 109 98 90 82 <br /> 930 76 ]0 <br /> 0 1241 930 744 620 532 465 414 372 338 310 286 266 <br /> 27 92,151 369 276 221 185 158 138 123 111 101 92 85 79 <br /> 1396 1047 938 609 509 523 465 410 391 340 322 299 <br /> 30 102,390 410 307 246 205 176 154 137 123 112 102 95 88 <br /> 1551 1163 930 775 665 582 517 465 423 388 358 332 <br /> 36 122,868 492 369 295 246 211 184 164 748 134 123 113 105 <br /> A 1861 1396 1117 930 798 698 620 556 508 465 429 399 <br /> 40.5 138,226 554 418 332 277 237 208 185 166 151 138 128 119 <br /> 2094 1570 1256 1047 897 785 698 628 634 582 537 498 <br /> 45 153,585 615 461 369 307 263 230 205 184 168 154 142 132 <br /> 2326 1745 1398 1163 997 872 755 698 634 582 537 498 <br /> INLET OPENING 54 184,302 738 554 443 359 316 277 246 221 201 185 170 158 <br /> Di VUVE 2791 2094 1675 1396 1196 1047 930 837 761 696 644 598 <br /> Figured at 1 kW(3413 BTU)=4]Gallons at 10o-F temperature rise, <br /> 535 <br /> Model Tank Dimensions Inlet/ Approx.Ship. <br /> e Capacity Number A B C Outlet(NPT) Wt. <br /> al. litre in. I cm in. I cm in. cm in. cm Ib kg I <br /> DVE-52 50 189 55 3/4 142 21 3/4 55.2 27 68.6 1 1/4 3.2 265 120 <br /> DVE-80 80 300 601/4 1 153 1 251/2 1 64.8 31 78.7 11/4 1 3.2 1 280 11 127 <br /> DVE-120 119 450 621/4 158.1 291/2 75.0 35 88.9 11/4 3.2 390 177 <br /> Model Numbers Number Element Full Load Current In Amperes <br /> kW Tank Capacity in Gallons Of Sin le Phase Three Phase <br /> Input 50 1 80 119 Elements Wattage 208V 240V I 277V I 480V 208V I 240V 480V <br /> 6 DVE-52.6 DVE-80-6 DVE-120-6 3 2,000 28.8 25.0 21.7 12.5 16.7 14.4 7.2 <br /> 9 DVE-52-9 DVE-80-9 DVE-120-9 3 3,000 43.3 37.5 "32.5 18.8 25.0 21.7 10.8 <br /> 12 DVE-52-12 DVE-80-12 DVE-120-12 3 4,000 57.7 50.0 43.3 25.0 33.3 28.9 14.4 <br /> 13.5 DVE-52-13.5 DVE-80-13.5 DVE-120-13.5 3 4,500 64.9 56.3 ••48.7 28.1 37.5 32.5 16.2 <br /> 15 DVE-52.15 DVE-80-15 DVE-120-15 3 5,000 72.1 62.5 54.2 31.3 41.6 36.1 18.0 <br /> 18 DVE-52.18 DVE-80-18 DVE-120-18 3* 6,000 86.5 75.0 65.0 37.5 50.0 43.3 21.7 <br /> 24 DVE-52.24 DVE-80-24 DVE-120-24 6 4,000 115.4 100.0 86.6 50.0 66.6 57.7 28.9 <br /> 27 DVE-52-27 DVE-80-27 DVE-120-27 6 4,500 129.8 112.5 ••97.5 56.3 74.9 65.0 32.5 <br /> 30 DVE-52-30 DVE-80-30 DVE-120-30 6 5,000 144.2 125.0 108.3 62.5 83.3 72.2 36.1 <br /> 36 1 DVE-52-36 I DVE-80.36 I DVE-120-36 1 6 1 6,000 173.1 150.0 130.0 75.0 99.9 86.6 43.3 <br /> 40.5 DVE-52-40.5 DVE-80-00.5 DVE-120-40.5 9 4,500 194.7 168.8 "146.2 84.4 112.4 97.4 48.7 <br /> 45 DVE-52-45 DVE-80-45 DVE-120-45 9 5,000 216.3 187.5 162.5 93.8 124.9 108.3 54.1 <br /> 54 DVE-52-54 DVE-80-54 OVE-120-54 9 6,000 N/A 225.0 194.9 112.5 149.9 129.9 65.0 <br /> •208 volt models may contain three(3)additional elements.'•Elements available in incoloy only. <br /> SUGGESTED SPECIFICATION <br /> The heater(s)shall be Gold xi Commercial Electric Madel Number as manufactured by A.O.Smith Water Products Company or equivalent.Heaters)shall be rated at <br /> kW V phase,60 cycle AC listed by Underwriters'Laboratories and approved to the NSF Standard 5 by I.K.Water heater shall have LCD display <br /> with built-in diagnostic and troubleshooting intonation.Tani shall be(50,80 or 119)gallon capacity with 150 psi working pressure and equipped with dual extruded high density anodes. <br /> All internal surfaces of the heater(s)exposed to water shall be glass-lined with an alkaline boroolicate composition that has been fused to steel by firing ata temperature range of 1400°F to <br /> 1600°F.Electric heating elements shall be 24K Goldenrod medium watt density screw-in type with incoloy sheath and ceramic terminal black.Internal power circuit fusing shall be provided. <br /> Element operation shall be linear sequencing through individual magnetic contactors.Control circuit shall be factory fused and include an immersion thermistor temperature probe with built- <br /> in ECO control.Control cabinet and jacket shall be of baked enamel finish and shall provide PoII size control and element compartment for complete service and maintenance performance <br /> through front hinged compartment door,and enclose tank with foam insulation,l 114'inlet and outlet connection shall be provided.The heater tank shall have a three year limited warranty <br /> and controls and accessories shall have a one year limited warranty as outlined in the written warranty.Fully illustrated instruction manual to he included.For multiple installation,factory <br /> built manifold kits for heater installation(maximum of 4 heaters)shall be provided.Meets or exceeds the thermal efficiency and standby lass requirements of Me US.Department <br /> of Energy and current edition of ASHRAVIESNA 90.1. <br /> Water heater should incorporate the iCOM M IN System for remote monitoring,leake detection and fault alert. <br /> For Tech ne,I I nf arm ation and Automated Fax Service,call 800 527 1953 A 0 Smith Corporation reserves The right to make product changes or improvements without prior notice <br /> September 2010R Page 2 of 2 <br /> www.hotwater.com AOSCE15200 <br />
The URL can be used to link to this page
Your browser does not support the video tag.