CA GREEN CODE REQUIREMENTS I m
<br /> 1. PER CALGREEN SECTION 5.303.2, PLUMBING FIXTURES SHALL MEET THE MAXIMUM FLOW RATE VALUES SHOWN
<br /> IN TABLE 5.303.2.3. EXCEPTION: BUILDING THAT DEMONSTRATE 20% OVERALL WATER USE REDUCTION. IN THIS
<br /> CASE, A CALCULATION DEMONSTRATING A 2% REDUCTION IN THE BUILDING "WATER USE BASELINE," AS
<br /> ESTABLISHED IN TABLE 5.303.3 SHALL APPLY TO NEW FIXTURES IN ADDITIONS OR AREAS OF ALTERATIONS TO
<br /> THE BUILDING.
<br /> MAXIMUM FIXTURE FLOW RATES:
<br /> FIXTURE TYPE MAXIMUM FLOW RATE
<br /> LAVATORY FAUCETS-NONRESIDENTIAL 0.5 GPM ® 60 PSI
<br /> KITCHEN FAUCETS 1.8 GPM @ 60 PSI z
<br /> METERING FAUCETS 0.25 GALLONS/CYCLE O
<br /> WATER CLOSETS 1.28 GALLONS/FLUSH
<br /> URINALS 0.5 GALLONS/FLUSH U
<br /> w
<br /> 2. PER CALGREEN SECTION 5.303.3.1, THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT
<br /> EXCEED 1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE PERFORMANCE
<br /> CRITERIA OF THE US EPA WATER SENSE SPECIFICATION FOR TANK-TYPE TOILETS. NOTE: THE EFFECTIVE
<br /> FLUSH VOLUME OF DUAL FLUSH TOILETS IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO
<br /> REDUCES FLUSHES AND ONE FULL FLUSH.
<br /> 3. PROVIDE READILY ACCESSIBLE AREAS THAT SERVE THE ENTIRE BUILDING AND ARE IDENTIFIED FOR THE
<br /> DEPOSITING, STORAGE, AND COLLECTION OF NONHAZARDOUS MATERIALS FOR RECYCLING. PER SECTION
<br /> 5.410.1.1 ANY ADDITION OR ALTERATION RESULTING IN LESS THAN A 30% INCREASE IN THE TENANT SPACE
<br /> FLOOR AREA IS EXEMPT FROM THIS REQUIREMENT.
<br /> 4. PER CALGREEN SECTION 5.504.3, AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE
<br /> CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING, AND VENTILATING EQUIPMENT, ALL
<br /> DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, w
<br /> SHEET METAL, OR OTHER APPROVED METHODS TO REDUCE THE AMOUNT OF DUST, WATER, AND DEBRIS WHICH I Q
<br /> MAY ENTER THE SYSTEM. o
<br /> 5. PER CALGREEN SECTION 5.504.4.1, ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS,
<br /> SEALANT PRIMERS AND CAULKS SHALL COMPLY WITH TABLE 5.504.4.1 AND 5.504.4.2. I w
<br /> SEALANT VOC LIMIT: ARCHITECT OF RECORD:
<br /> ARCHITECTURAL 250
<br /> MARINE DECK 760 ARCy/T
<br /> NONMEMBRANE ROOF 300 CRAIG S. �n
<br /> ROADWAY 250 ;�� BLUME
<br /> SINGLE-PLY ROOF MEMBRANE 450
<br /> OTHER 420 * NO-.-C-31661
<br /> REN.3/31/2021
<br /> y
<br /> 6. PER CALGREEN SECTION 5.504.4.3, ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH TABLE
<br /> 5.504.4.3.
<br /> 'GdoJ'/ 0 y
<br /> VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS:
<br /> INDOOR CARPET ADHESIVES 50 pj
<br /> CARPET PAD ADHESIVES 50 NAPA Z
<br /> OUTDOOR CARPET ADHESIVES 150 O
<br /> im
<br /> WOOD FLOORING ADHESIVES 100 3
<br /> RUBBER FLOOR ADHESIVES 60
<br /> SUBFLOOR ADHESIVES 50
<br /> CERAMIC TILE ADHESIVES 65
<br /> VCT AND ASPHALT TILE ADHESIVES 50
<br /> DRYWALL AND PANEL ADHESIVES 50
<br /> COVE BASE ADHESIVES 50
<br /> MULTIPURPOSE CONSTRUCTION ADHESIVES 70 W
<br /> STRUCTURAL GLAZING ADHESIVES 100 m
<br /> SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 o P
<br /> OTHER ADHESIVES NOT SPECIFICALLY LISTED 50 O U
<br /> s
<br /> SPECIALTY APPLICATIONS PVC WELDING 510 a w
<br /> w 0 3
<br /> CPVC WELDING 490 .N o� 1
<br /> ABS WELDING 325
<br /> PLASTIC CEMENT WELDING 250
<br /> ADHESIVE PRIMER FOR PLASTIC 550 0 �, ; p o w 0) N
<br /> CONTACT ADHESIVE 80 Q CJ 0 2 t 0 ° ' o
<br /> SPECIAL PURPOSE CONTACT ADHESIVE 250 ° J a 0 p CO
<br /> STRUCTURAL WOOD MEMBER ADHESIVE 140 0 ° Ls
<br /> C'_ O N'pp V a p
<br /> TOP AND TRIM ADHESIVE 250 J E ° N c
<br /> SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 0 !, o 3 N 'o� �,
<br /> PLASTIC FOAMS 50 o °
<br /> 0 0
<br /> POROUS MATERIAL (EXCEPT WOOD) 50 a, 'o
<br /> WOOD 30 0 , u o c°'rn a
<br /> N o C_•;6 p y Lo
<br /> FIBERGLASS 80 0 o,o o °c C
<br /> troy, ° pc
<br /> 7. PER CALGREEN SECTION 5.504.4.3.2, VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED .� m- " °' m p
<br /> _ c c+.
<br /> AT THE REQUEST OF THE ENFORCING AGENCY. DOCUMENTATION MAY INCLUDE, BUT IS NOT LIMITED TO, THE v 0'c�' o 0, o
<br /> p °+x �
<br /> FOLLOWING: L ° - N E N
<br /> 1. MANUFACTURER'S PRODUCT SPECIFICATION ° J~ `- ° 0
<br /> 2. FIELD VERIFICATION OF ON-SITE PRODUCT CONTAINERS _- Q � c a o
<br /> ° j•�°- N p 10 c
<br /> O w
<br /> taA'�'O V O U N
<br /> 8. PER CALGREEN SECTION 5.504.4.6, RESILIENT FLOORING SYSTEMS SHALL COMPLY WITH THE VOC-EMISSION
<br /> � p� °aai
<br /> LIMITS DEFINED IN THE 2012 CHPS CRITERIA AND LISTEN ON ITS HIGH PERFORMANCE PRODUCTS DATABASE, o 0 0 �, ,o a
<br /> PRODUCTS COMPLIANT WITH CHPS CRITERIA CERTIFIED UNDER THE GREENGAURD CHILDREN & SCHOOLS V o T O
<br /> PROGRAM, CERTIFIED UNDER THE FLOORSCORE PROGRAM OF THE RESILIENT FLOOR COVERING INSTITUTE, OR �'��`, ° a�
<br /> °
<br /> SHALL MEET CALIFORNIA DEPARTMENT OF PUBLIC HEALTH 2010 SPECIFICATION. O 3 -
<br /> w p 0 3 p o p p p
<br /> Q01 00
<br /> 9. PER CALGREEN SECTION 5.508.1, RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65 PERCENT OF THE a (n Ho r Z °
<br /> NONHAZARDOUS CONSTRUCTION OR DEMOLITION WASTE IN ACCORDANCE WITH SECTION 5.408.1.1, 5.408.1.2, OR w s �•- O °0 N 0
<br /> �
<br /> 5.408.1.3 OR MEET A LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE, WHICHEVER IS a
<br /> MORE STRINGENT.
<br /> ui
<br /> �p m z 0 U ON
<br /> 10. PER CALGREEN SECTION 5.504.1.3, TEMPORARY VENTILATION. THE PERMANENT HVAC SYSTEM 0° �`' o o vii \ - (oo
<br /> SHALL ONLY BE USED DURING CONSTRUCTION IF NECESSARY TO CONDITION THE BUILDING OR Q N N � � `� o a N
<br /> AREAS OF ADDITION OR ALTERATION WITHIN THE REQUIRED TEMPERATURE RANGE FOR MATERIAL o v' Q a 6 v
<br /> AND EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN Q o ::5 [if 0 0 C)
<br /> AIR FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8, BASED ON ASHRAE `n
<br /> 52.2-1999, OR AN AVERAGE EFFICIENCY OF 30 PERCENT BASED ON ASHRAE 52.1-1992. REPLACE N
<br /> ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY, OR, IF THE BUILDING IS OCCUPIED DURING
<br /> ALTERATION AT THE CONCLUSION OF CONSTRUCTION.
<br /> Q
<br /> U
<br /> 11. PER CALGREEN SECTION 5.504.3, COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL o
<br /> EQUIPMENT DURING CONSTRUCTION. AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE
<br /> CONSTRUCTION SITE UNTIL FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT, ALL DUCT
<br /> AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC,
<br /> SHEETMETAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF cf)
<br /> DUST, WATER AND DEBRIS WHICH MAY ENTER THE SYSTEM. Q
<br /> U uio
<br /> of
<br /> 12. PER CALGREEN SECTION 5.504.7, ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL. WHERE OUTDOOR U ~a o
<br /> AREAS ARE PROVIDED FOR SMOKING, PROHIBIT SMOKING WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR QJ w
<br /> INTAKES AND OPERABLE WINDOWS AND WITHIN THE BUILDING AS ALREADY PROHIBITED BY OTHER LAWS OR m C D o z Q
<br /> REGULATIONS; OR AS ENFORCED BY ORDINANCES, REGULATIONS OR POLICIES OF ANY CITY, COUNTY, CITY z O w U
<br /> AND COUNTY, CALIFORNIA COMMUNITY COLLEGE, CAMPUS OF THE CALIFORNIA STATE UNIVERSITY, OR CAMPUS 0 uj D �, N
<br /> OF THE UNIVERSITY OF CALIFORNIA, WHICHEVER ARE MORE STRINGENT. WHEN ORDINANCES, REGULATIONS OR ? L w
<br /> POLICIES ARE NOT IN PLACE, POST SIGNAGE TO INFORM BUILDING OCCUPANTS OF THE PROHIBITIONS. O w o 0
<br /> LL m w Q J
<br /> z LL w
<br /> O CD o N
<br /> W J w
<br /> Z Z U U
<br /> O) [ w w O
<br /> /� 00
<br /> Fh 00
<br /> U)/ E2 M L
<br /> Ld
<br /> Q W 0 O w N O
<br /> LOGN1 . 1
<br /> _
<br /> 0 GENERAL NOTES