CA GREEN CODE REQUIREMENTS ,
<br /> 1. PER CALGREEN SECTION 5.303.2, PLUMBING FIXTURES SHALL MEET THE MAXIMUM FLOW RATE VALUES SHOWN
<br /> IN TABLE 5.303.2.3. EXCEPTION: BUILDING THAT DEMONSTRATE 20% OVERALL WATER USE REDUCTION. IN THIS
<br /> CASE, A CALCULATION DEMONSTRATING A 2% REDUCTION IN THE BUILDING "WATER USE BASELINE," AS
<br /> ESTABLISHED IN TABLE 5.303.3 SHALL APPLY TO NEW FIXTURES IN ADDITIONS OR AREAS OF ALTERATIONS TO
<br /> THE BUILDING.
<br /> MAXIMUM FIXTURE FLOW RATES:
<br /> FIXTURE TYPE MAXIMUM FLOW RATE
<br /> LAVATORY FAUCETS-NONRESIDENTIAL 0.5 GPM ® 60 PSI
<br /> KITCHEN FAUCETS 1.8 GPM @ 60 PSI z
<br /> METERING FAUCETS 0.25 GALLONS/CYCLE 0
<br /> WATER CLOSETS 1.28 GALLONS/FLUSH
<br /> URINALS 0.5 GALLONS/FLUSH
<br /> cn
<br /> w
<br /> 2. PER CALGREEN SECTION 5.303.3.1, THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT
<br /> EXCEED 1.28 GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE PERFORMANCE
<br /> CRITERIA OF THE US EPA WATER SENSE SPECIFICATION FOR TANK-TYPE TOILETS. NOTE: THE EFFECTIVE
<br /> FLUSH VOLUME OF DUAL FLUSH TOILETS IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO
<br /> REDUCES FLUSHES AND ONE FULL FLUSH.
<br /> 3. PROVIDE READILY ACCESSIBLE AREAS THAT SERVE THE ENTIRE BUILDING AND ARE IDENTIFIED FOR THE
<br /> DEPOSITING, STORAGE, AND COLLECTION OF NONHAZARDOUS MATERIALS FOR RECYCLING. PER SECTION
<br /> 5.410.1.1 ANY ADDITION OR ALTERATION RESULTING IN LESS THAN A 30% INCREASE IN THE TENANT SPACE
<br /> FLOOR AREA IS EXEMPT FROM THIS REQUIREMENT.
<br /> 4. PER CALGREEN SECTION 5.504.3, AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE
<br /> CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING, COOLING, AND VENTILATING EQUIPMENT, ALL
<br /> DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, w
<br /> SHEET METAL, OR OTHER APPROVED METHODS TO REDUCE THE AMOUNT OF DUST, WATER, AND DEBRIS WHICH Q
<br /> MAY ENTER THE SYSTEM. o
<br /> 5. PER CALGREEN SECTION 5.504.4.1, ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE PRIMERS, SEALANTS,
<br /> SEALANT PRIMERS AND CAULKS SHALL COMPLY WITH TABLE 5.504.4.1 AND 5.504.4.2. w
<br /> G'
<br /> SEALANT VOC LIMIT: ARCHITECT OF RECORD:
<br /> ARCHITECTURAL 250
<br /> MARINE DECK 760 ,�p ARC,y��
<br /> NONMEMBRANE ROOF 300 �
<br /> ROADWAY 250 J PATRICKG
<br /> EES
<br /> SINGLE-PLY ROOF MEMBRANE 450 * C-31531
<br /> OTHER 420
<br /> N 03/31/23 �Q
<br /> RENEWAL
<br /> 6. PER CALGREEN SECTION 5.504.4.3, ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH TABLE �T DATE 0
<br /> 5.504.4.3.
<br /> 11/22/2021
<br /> VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS:
<br /> INDOOR CARPET ADHESIVES 50 a
<br /> gird
<br /> CARPET PAD ADHESIVES 50
<br /> OUTDOOR CARPET ADHESIVES 150 O Q
<br /> WOOD FLOORING ADHESIVES 100 o
<br /> RUBBER FLOOR ADHESIVES 60
<br /> SUBFLOOR ADHESIVES 50
<br /> CERAMIC TILE ADHESIVES 65
<br /> VCT AND ASPHALT TILE ADHESIVES 50
<br /> DRYWALL AND PANEL ADHESIVES 50
<br /> COVE BASE ADHESIVES 50 'kin
<br /> CONSTRUCTION ADHESIVES 70 W
<br /> STRUCTURAL GLAZING ADHESIVES 100m /■�
<br /> SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 �■ P
<br /> OTHER ADHESIVES NOT SPECIFICALLY LISTED 50 O a o
<br /> a
<br /> SPECIALTY APPLICATIONS PVC WELDING 510 Uj
<br /> CPVC WELDING 490 a ci o 3
<br /> � 5
<br /> ABS WELDING 325
<br /> PLASTIC CEMENT WELDING 250
<br /> ADHESIVE PRIMER FOR PLASTIC 550 o z. °
<br /> CONTACT ADHESIVE 80 a o `° v c o co_'o
<br /> SPECIAL PURPOSE CONTACT ADHESIVE 250 pJ a .0° - 0-0
<br /> STRUCTURAL WOOD MEMBER ADHESIVE 140 v o L aµ; ;u o 0
<br /> TOP AND TRIM ADHESIVE 250 J ° °'
<br /> SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 300 !, ° A? 3 N a N
<br /> PLASTIC FOAMS 50 o (o
<br /> POROUS MATERIAL (EXCEPT WOOD) 50 °' .0 3 L O°� d
<br /> WOOD 30 0 2 . o,� o �'
<br /> FIBERGLASS 80 O 0 _ 3 °'
<br /> U p
<br /> t t ° y O C
<br /> 7. PER CALGREEN SECTION 5.504.4.3.2, VERIFICATION OF COMPLIANCE WITH THIS SECTION SHALL BE PROVIDED V� N ;a N o
<br /> 'O O 5-6 E- c
<br /> AT THE REQUEST OF THE ENFORCING AGENCY. DOCUMENTATION MAY INCLUDE, BUT IS NOT LIMITED TO, THE O c p'c o N O
<br /> ° °. x.
<br /> FOLLOWING: c�s ° 0 °0 N
<br /> 1. MANUFACTURER'S PRODUCT SPECIFICATION M ° J~ c- °
<br /> 2. FIELD VERIFICATION OF ON-SITE PRODUCT CONTAINERS a.2 ° � `p
<br /> OU �0 O p � C w
<br /> (Jl '000 ° 0 p N
<br /> 8. PER CALGREEN SECTION 5.504.4.6, RESILIENT FLOORING SYSTEMS SHALL COMPLY WITH THE VOC-EMISSION
<br /> �-5 aai L E
<br /> LIMITS DEFINED IN THE 2012 CHPS CRITERIA AND LISTEN ON ITS HIGH PERFORMANCE PRODUCTS DATABASE, ° ° o ° , p a E
<br /> PRODUCTS COMPLIANT WITH CHPS CRITERIA CERTIFIED UNDER THE GREENGAURD CHILDREN & SCHOOLS V
<br /> o v, °
<br /> PROGRAM, CERTIFIED UNDER THE FLOORSCORE PROGRAM OF THE RESILIENT FLOOR COVERING INSTITUTE, OR g'�° ° ca,
<br /> SHALL MEET CALIFORNIA DEPARTMENT OF PUBLIC HEALTH 2010 SPECIFICATION. 0 'o o L o.2'3 0 0
<br /> o a"
<br /> ® 3 o i .
<br /> 9. PER CALGREEN SECTION 5.508.1, RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF 65 PERCENT OF THE a o.r L_Uol z °
<br /> NONHAZARDOUS CONSTRUCTION OR DEMOLITION WASTE IN ACCORDANCE WITH SECTION 5.408.1.1, 5.408.1.2, OR w t L•- p p t °t
<br /> c
<br /> 5.408.1.3 OR MEET A LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE, WHICHEVER IS a
<br /> MORE STRINGENT. zu�
<br /> w
<br /> >_ p m z w U O
<br /> 10. PER CALGREEN SECTION 5.504.1.3, TEMPORARY VENTILATION. THE PERMANENT HVAC SYSTEM 00 ``' O o J Ul co
<br /> SHALL ONLY BE USED DURING CONSTRUCTION IF NECESSARY TO CONDITION THE BUILDING OR � N `�' � 0- `� o a
<br /> AREAS OF ADDITION OR ALTERATION WITHIN THE REQUIRED TEMPERATURE RANGE FOR MATERIAL �' Q > Q o
<br /> AND EQUIPMENT INSTALLATION. IF THE HVAC SYSTEM IS USED DURING CONSTRUCTION, USE RETURN Q o � bi o N
<br /> AIR FILTERS WITH A MINIMUM EFFICIENCY REPORTING VALUE (MERV) OF 8, BASED ON ASHRAE
<br /> 52.2-1999, OR AN AVERAGE EFFICIENCY OF 30 PERCENT BASED ON ASHRAE 52.1-1992. REPLACE N
<br /> ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY, OR, IF THE BUILDING IS OCCUPIED DURING
<br /> ALTERATION AT THE CONCLUSION OF CONSTRUCTION.
<br /> d
<br /> v
<br /> 11. PER CALGREEN SECTION 5.504.3, COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL o
<br /> EQUIPMENT DURING CONSTRUCTION. AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE
<br /> CONSTRUCTION SITE UNTIL FINAL STARTUP OF THE HEATING, COOLING AND VENTILATING EQUIPMENT, ALL DUCT
<br /> AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC,
<br /> SHEETMETAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF 07
<br /> DUST, WATER AND DEBRIS WHICH MAY ENTER THE SYSTEM. Q
<br /> uj
<br /> U o
<br /> 12. PER CALGREEN SECTION 5.504.7, ENVIRONMENTAL TOBACCO SMOKE (ETS) CONTROL. WHERE OUTDOOR u a o
<br /> AREAS ARE PROVIDED FOR SMOKING, PROHIBIT SMOKING WITHIN 25 FEET OF BUILDING ENTRIES, OUTDOOR AIR QJ w
<br /> INTAKES AND OPERABLE WINDOWS AND WITHIN THE BUILDING AS ALREADY PROHIBITED BY OTHER LAWS OR COU o z Q
<br /> REGULATIONS; OR AS ENFORCED BY ORDINANCES, REGULATIONS OR POLICIES OF ANY CITY, COUNTY, CITY z
<br /> AND COUNTY, CALIFORNIA COMMUNITY COLLEGE, CAMPUS OF THE CALIFORNIA STATE UNIVERSITY, OR CAMPUS Ld cn
<br /> w �
<br /> OF THE UNIVERSITY OF CALIFORNIA, WHICHEVER ARE MORE STRINGENT. WHEN ORDINANCES, REGULATIONS OR Q J w o
<br /> POLICIES ARE NOT IN PLACE, POST SIGNAGE TO INFORM BUILDING OCCUPANTS OF THE PROHIBITIONS. U) O w o
<br /> LL m w Q J
<br /> Z W M
<br /> U U o N
<br /> W J W
<br /> z Z U U
<br /> 0-) 0 Of w 00O
<br /> Fh 00
<br /> cn xcn 0
<br /> Wa
<br /> W 0 O LJ Ul O
<br /> w
<br /> O GN1 . 1
<br /> _
<br /> cf) GENERAL NOTES