1625
FACILITY_ID
FA0023696
FACILITY_NAME
MCDONALDS 36681
STREET_NUMBER
1613
Direction
S
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
LODI
Zip
95242
APN
04931058
CURRENT_STATUS
01
SITE_LOCATION
1613 S LOWER SACRAMENTO RD
P_LOCATION
02
QC Status
Approved
Scanner
SJGOV\jcastaneda
Supplemental fields
FilePath
\MIGRATIONS\L\LOWER SACRAMENTO\1613\PR0541351\PLANS.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Q m <br /> POS & COD ISOLATED GROUND/DEDICATED CIRCUIT <br /> KEY NOTES <br /> 4 SOLID #12 AWG THIS IS THE ONLY POINT WHERE THE ISOLATED <br /> • SHOWS CONNECTION/BONDING POINT ONLY. <br /> CONDUCTORS 8 ❑1 EQUIPMENT GROUNDING CONDUCTOR SHALL BE <br /> CONNECTED TO THE BUILDING'S GROUNDING SYSTEM. <br /> SEE BUILDING GROUNDING DETAIL THIS SHEET. <br /> (ORDER AREA) ELECTRICAL (P C K U P AREA) SERVICE ENTRANCE 3 PANEL CP 9 1-1/2" <br /> -1 P2 GND METAL 1CONDUIT:CU ISOLATED1CU + 1-#6 CU <br /> RACEWAY (ADJUST (TYPICALLY MDP) COMPUTER ONLY <br /> TO BE 1 ESS A B C BLK A B G WH 0 ALL ISOLATED GROUND/ DEDICATED CIRCUIT <br /> THAN COUNTER WHT <br /> 100A-3P RED RECEPTACLE COVER PLATES SHALL BE ORANGE <br /> GRN )LW STRIP HUBBELL PJ7CO (SINGLE), PJ8CO (ONE DUPLEX) OR Z <br /> LENGTH BLU CRN PJ82CO (TWO DUPLEX) MARKED "COMPUTER ONLY". O <br /> WHT METAL JUNCTIO 11 <br /> 4 AWG GRN nW STRIP BOX METAL CONDUIT SHALL CONTAIN ONLY P.O.S. CIRCUIT <br /> CRN 12 CONDUCTORS (DEDICATED CIRCUIT). ONLY USE RIGIDNON-METD' <br /> J-BOX S ELECTRICAL J-BOX S REQUIRED ABYCLOCAL CODECONDUIT . U)GRADE WHEN U) <br /> FOR POWER _ _ _ _ RACEWAY TO BE FOR POWER N 5 13 0 <br /> PULL BOX INSTALLED ON PULL BOX CRN rLw EQUIPMENT GROUNDING BONDING CONDUCTOR <br /> HORIZONTAL 6 (TYPICAL) <br /> FOR DATA FOR DATA <br /> FRAMING ® ® Be N ❑ ISOLATED GROUND BUS, ELECTRICALLY INSULATED <br /> 0 0 0 o MEMBER OR A o 7 FROM PANEL ENCLOSURE USED TO TERMINATE ONLY <br /> PIECE OF ISOLATED EQUIPMENT GROUNDING CONDUCTORS. <br /> UNISTRUT ❑ ALL CONDUCTORS SHALL BE SOLID COPPER AND z <br /> 1 8 TERMINATED TO THEIR APPROPRIATE TERMINAL SCREWS Cn <br /> BY WRAPPING THE CONDUCTOR COMPLETELY AROUND > <br /> n j <br /> THE SCREW BARREL AND TIGHTENING THE SCREW PER <br /> 2 MANUFACTURER'S TORQUE SPECIFICATIONS. <br /> yy Bc� 99 <br /> ISOLATED GROUND RECEPTACLE <br /> 8 NOTES HUBBELL-IG4700,IG4710,IG5262 OR IG5261. SEE z <br /> ROUGH IN SCHEDULE FOR THE APPROPRIATE 0 <br /> 1. ALL P.O.S. EQUIPMENT (COMPUTERS,PRINTERS,MONITORS RECEPTACLE TO USE. <br /> KVS, MODEM, HUB & COD) SHALL BE POWERED FROM 6. EC SHALL VERIFY THAT SUBPANEL CP DOES NOT CONTAIN N <br /> SYMBOL CATALOG # DESCRIPTION QUANTITY <br /> THE COMPUTER PANEL. ANY ILLEGAL NEUTRAL TO GROUND BONDS. 0 ISOLATED GREEN GROUND SCREW. N w <br /> 7. PANEL CP SHALL ONLY BE USED TO POWER SENSITIVE 11 ISOLATED EQUIPMENT GROUNDING CONDUCTOR (GRN Q <br /> D HBLALU57DR & IG4700 RECEPTACLE COVERPLATE WITH ORANGE, 1 PER ISOLATED GROUND RECEPTACLE ALL OTHER COMPUTER/DIGITAL EQUIPMENT SHALL BE ❑ W/YLw STRIP) o <br /> TWIST LOCK, ISOLATED GROUND POWERED FROM PHASE "A" IN THE COMPUTER PANEL. ELECTRONIC EQUIPMENT, AS OUTLINED IN NOTE #1. IT <br /> SHALL NOT BE USED TO POWER ANY OTHER LOADS. 12 NEUTRAL CONDUCTOR TERMINATED ON SILVER SCREW. <br /> DUPLEX RECEPTACLE 2. ISOLATED GROUND INSTALLATION SHALL COMPLY WITH THE > <br /> �® HBLALU57DR & 5-15R RECEPTACLE COVERPLATE WITH 1 REQUIREMENTS of NEC SECTION 250 . <br /> 8. IT IS A SAFETY HAZARD AND AN NEC VIOLATION FOR THE 13 PHASE CONDUCTOR TERMINATED ON BRASS SCREW m W <br /> POS SYSTEM TO HAVE ITS OWN INDEPENDENT GROUNDING � <br /> STRAIGHT BLADE DUPLEX RECEPTACLE3. EACH 20 AMP CIRCUIT SHALL HAVE IT'S OWN ISOLATED ROD. IF AN INDEPENDENT GROUND ROD IS FOUND FOR ENGINEER OF RECORD: <br /> D HBLALU57LPB COMMUNICATIONS COVERPLATE 1 PER REGISTER & 1 FOR DUAL POINT & 1 FOR ANALOG WIRELESS OPTION EQUIPMENT GROUNDING CONDUCTOR. THE POS SYSTEM, IT SHALL BE BONDED TO THE <br /> BUILDING GROUNDING SYSTEM. <br /> D HBLALU57BL BLANK COVERPLATE AS NECESSARY TO FILL RACEWAY 4. ENTIRE GROUNDING SYSTEM SHALL COMPLY WITH NEC <br /> D HBLALU7620B03M290 3' SECTION OF RACEWAY. INCLUDES AS NECESSARY TO MAKE ORDER COUNTER RACEWAY 1 ' LESS THEN COUNTER ARTICLE 250 AND MCDONALD's BUILDING GROUNDING 9 R <br /> COUPLERS LENGTH. INSTALL (2) 2' OR 3' RACEWAY AT PICKUP DETAIL. <br /> D HBLALU7620B02M290 2' SECTION OF RACEWAY INCLUDES AS NECESSARY TO MAKE ORDER COUNTER RACEWAY 1 ' LESS THEN COUNTER 5. EC SHALL VERIFY CORRECT POLARITY AT RECEPTACLE. 7 <br /> COUPLERS LENGTH. INSTALL (2) 2' OR 3' RACEWAY AT PICKUP <br /> ® HBLALU761OB BLANK END FITTING AS NEEDED <br /> OF CAt�F� <br /> HBLALU501OB2M2 SERVICE ENTRANCE FITTING & BUSHING AS NEEDED 11/12/21 <br /> FOR DATA CABLES <br /> N/A HBLALU5701 COUPLER (INCLUDED WITH RACEWAY RECEIVE 1 PAIR PER RACEWAY SECTION W O 1 <br /> � w <br /> SECTION) o <br /> N/A HBLALU5709 GROUND ADAPTER AS NEEDED PB = Pullbox SIF = Verify In FieldJB = Junctction Box ELECTRICAL SCHEDULE so <br /> Q <br /> Junction <br /> EC = Electrical Contractor <br /> NOTES: TAG # QTY DESCRIPTION VOLT/PH FLA BRK SIZE COND/WIRE PNL/CCT RECEP TYPE HGT AFF REQUIREMENTS & REMARKS <br /> 1 . RACEWAY AND RECEPTACLES TO BE PROVIDED WITH MODULAR FRONT COUNTER, INSTALLED BY CONTRACTOR. 004.2OE3 2 MENU BOARD - DIGITAL 120/1 5.3 20A - - (2) IG5262 SEE PLAN SEE LAYOUT FOR GANGED OUTLET CONFIGURATION <br /> ISOLATE <br /> 2. DETAIL SHOWN IS ATYPICAL CONFIGURATION ONLY. SITE SPECIFICS MIGHT CAUSE DEVIATIONS. SHORTER COUNTERS MAY REQUIRE CONTRACTOR 004.21 El z MENU BOARD - DIGITAL - MEDIA PLAYER 120/1 1.0 zoA - - (2) Ics262 SEE PLAN SEE LAYOUT FOR GANGED OUTLET CONFIGURATION <br /> ISOLATED <br /> TO CUT RACEWAY FOR RACEWAY TO BE 1 ' SHORTER THAN COUNTER. 216.05E9 1 ORB MONITOR 120/1 1.5EA 20A - - (1) IG4700 SEE PLAN SEE LAYOUT FOR GANGED OUTLET CONFIGURATION ILI. <br /> ISOLATED <br /> W <br /> JB WITH ONE (1) OPTION 2: m > u <br /> 1/2" CONDUIT TO 216.05 E9 JB WITH ONE (1) 2 1/2" RECESSED 4X12 ALUMINUM FIXED BLADE o <br /> [LOUVER TO EXHAUST INTO CAVITY. GC TO o a N <br /> ABOVE CEILING WITH CONDUIT TO ABOVE CEILING WITH w - '�o <br /> 0 , ( TYP . ) BUSHINGS FOR DATA 4.20 E3 BUSHINGS FOR DATA CABLES PROVIDE (1) LOUVER PER DMB. CENTER Q O 'o Q o <br /> CABLES AROUND PROPOSED BRACKET LOCATION d c m �l u <br /> U o, <br /> C3 w <br /> _ _ �IIII� __ _ B/ CEILING w <br /> EQ EQ IF 3'-6" ��F� 6. SEE RCP w <br /> (° <br /> 11 ° <br /> +-++/2. 0- ,zi- <br /> 0DJ <br /> � <br /> o � <br /> ° <br /> �L - E3 - o J o E-oo U o <br /> OPTION <br /> �- 4" CONDUIT SLEEVE THROUGH -6" 6'-+ <br /> ` VALANCE WALL TO ALLOW FOR c a i <br /> . PASS THROUGH OF DATA CABLE. o F ° ° o <br /> DUAL POINT PICK-UP ,l ` ( 751 I PROVIDE BUSHING ON EACH END.PASS-THROUGGLED 0 o o•E Q <br /> A `` 7 CI r? {I u ICr AS NEEDED TOHCOORDINATE CAN BE N WITH 0 �-0 <br /> STATION OVERSHELF C 0 0 - o L <br /> NEW ELECTRICAL ELECTRICAL v 0 _ L o a <br /> RECEPTACLES FOR MINI r RECEPTACLE FOR DRB. P CEILING BEHIND ANCONDISIONS O ° o ° ° 0 ° <br /> ORB AND SCANNER 701.13 E3 VERIFY LOCATION IN � � = 0� <br /> NEW ELECTRICAL �,/� <br /> CEILING. <br /> O C U O O O <br /> RECEPTACLE FOR ORB. -- - <br /> O" X+ <br /> z 4" 14 3 0" 2'-7„ 2" ---J <br /> VERIFY LOCATION IN a <br /> M <br /> 3'-0" MI4J. 8" IN. ° __j <br /> •� ° o o a <br /> CEILING. 2'-8" MIN. 2'- <br /> � ra 1-i L-1 r.� r� ra r� r,� <br /> CD m Zo 131 ul co cr1 co 0 c4 cs1 4'-0" STD. 3'-0" STD. 3'-0" STD. 0 Q c <br /> CD Q C?0 0 0Q 00 00 0 _D <br /> j + cP o o o p ca o 0 0 p t5'-0" MAX. 3'-0" 7"j-4" MAX. 3'-4' MAX. '-2' T/FINISHED FLOOR O 0 0 0 ° <br /> O D 1,7_1 c�1 �, c�1 D O Aoa HOLO ELEV. + o'-o" Q °U o L U <br /> F� m rn rnrn mrn mrn 3" ( } v 2 - o- <br /> -� I -� OVERALL COUNTER LENGTH VARIES EXISTING EQUIPMENT QUARRY TILE COVE BASE Q a <br /> SEE CHART BELOW ALT: SCHLUTER DILEX-AHK 0 0 o <br /> o e OVERALL COUNTER LENGTH VARIES o 0 0 <br /> FRONT COUNTER ELECTRICAL ROUGH-INS SEE CHART aELow FRONT COUNTER WITH DUAL POINT INCORPORATED RECESSED MENU BOARDS o L 8L,0° <br /> NOTE: OPTION 1 IS PREFERRED IF AREA BEHIND BOARDS IS A ° o,�° <br /> > x 1111= ws NON-CUSTOMER AREA AND MEDIA PLAYERS WON'T BE INSTALLED ABOVE o o (D 3 0 <br /> NTS FOOD PREP. SLEEVES SHOULD NOT BE INSTALLED WITHIN CUSTOMER 3 0 o E ° L <br /> LLJ <br /> VIEW. IF AREA BEHIND MENU BOARDS IS DINING, RESTROOMS, OR ® a i ° iv o <br /> SAMPLE ELECTRICAL SCHEDULE OTHER CUSTOMER-FACING LOCATION, USE OPTION 2. <br /> Q U) Q° 7 co (U_> U <br /> O L - N L N <br /> TAG # CTY DESCRIPTION VOLT/PH FLA BRK SIZE GOND/WIRE PNL/CCT RECEP TYPE HGT AFF REQUIREMENTS & REMARK'S w _C: � ° °� ° <br /> w <br /> 215.01DE1 4 POS PC HARDWARE - FRUNT COUNTER 120/x1 3.D EA. 20A 1/2"C-2#12IG CP:17 IC47DD 2'-D° EC TO RUN 3/4" COND IN WALL FOR FLUSH MTD SPCL. RECEP <br /> ISOLATED FOR KEYSTATIONS (MONITOR,CPU & CASH DRAWERS) w <br /> OPTION 2: JB WITH ONE (1) 1" CONDUIT Q °� m O o °� U O <br /> 215,101 1 POS PC HARDWARE - FRONT COUNTER DATA CABLE - - - - 400 PB 1'-B" EXTEND 2 1/2" CONDUIT UNDER SLAB TO 215.ODE7 FOR POS DATA ACCESSORY o w <br /> CABLES JB WITH TWO (2) 2 TO ABOVE CEILING WITH m U) z C0 <br /> MONITOR ® ® • SYSTEM WITH 1/2" CONDUIT TO BUSHINGS FOR DATA CABLES D' w O o c O O <br /> 216.04E1 1 ORB MONITOR (MINI) 120/1 1.5 EA. 20A 1/2"C-2#121G OP:17 IC47DD 1'-6" - LEVELING z = N w Nm N <br /> BRACKET a a ABOVE CEILING WITH � n O LL <br /> ISOLATED a a CONTROL Q U w (Y w <br /> CLIPS TO BUSHINGS FOR DATA w > LSI <br /> 216.D5E1 1 ORB MONITOR 120X1 1.5 EA. 20A 1/2"C-2#121G CP:4 <br /> IG4700 FW SH ON - ACCESSORY ° ° o Q w Q c0 U <br /> ISOLATED CLC SYSTEM }]� [u] CABLES 4.21 E1 0 m o O <br /> ° V ® u ° U <br /> 219.ODE3 4 POS - RECEIPT PRINTER/CASHLESS 120X1 D.7 20A 1 f2"C-2#121G CP:4,8 SEE RMKS IC47DD 2'-D" FOR RECEIPT LOCATED IN FRONT COUNTER POWER FROM CP:4 IN o o co U <br /> ISOLATED PRESENTER'S BOOTH CP:4 MEDIA PLAYER <br /> 701.13E3 1 DCO - GENERAL PURPOSE 120X1 1.5 20A 1f2"C-2/12 AP-2:6 5-20R - ©� <br /> cv <br /> -B" u o j o N <br /> ❑❑ � <br /> DUAL POINT CONVERSION NOTES: �9 <br /> 1 , ADDITIONAL POWER FOR CREW MINI-ORB AND SCANNER LOCATED UNDER COUNTER. SEE 216,04/13ETAIL 1 (ELECTRICAL ROUGH-INS) BOTTOM OF VALANCE <br /> 2. ADDITIONAL POWER FOR CUSTOMER ORB MONITOR INSTALLED AT FACE OF SOFFIT. SEE 21 6.05/DETAIL 1 (ELECTRICAL ROUGH-INS) V-5" o <br /> ED . o o OPTION 1: HORIZONTAL DIMENSIONS w <br /> 3. SEQUENCE MENU BOARDS PER DUAL POINT STANDARDS o REFERENCED FROM LEFT <br /> 4. NON-SEEQ INSTALL - PICK-UP SHELF MATERIALS TO MATCH CBB CELL WITH 1 OF 12 APPROVED LAMINATE SELECTIONS. KES TO ORDER FROM DECOR 4" CONDUIT SLEEVE <br /> INSTALLATION THROUGH VALANCE WALL � <br /> COMPANY. (VERIFIED AT TIME OF SURVEY) MOUNTING SUPPORTS TO ALLOW FOR PASS <br /> 5. SEEQ INSTALL - PICK-UP SHELF MATERIALS TO MATCH DECOR FRONT COUNTER CORIAN SPECIFICATION, GC TO FABRICATE AND INSTALL TO THROUGH of DATA CABLE. Q <br /> *SECURE TO EXISITING STUDS OR 3/4" PLYWOOD BACKING PROVIDE BUSHING ON <br /> SPECIFICATIOhJS_ (LINEN OR RICE PAPER} EACH END. SLEEVE CAN U <br /> 6. SIGNAGE PACKAGE PROVIDED BY KES AND INSTALLED BY G.C. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS BE ANGLED WHEN E > 0 <br /> NECESSARY U Q o <br /> 7. ADA PLATFORM SOLUTION DOES NOT MEET ADA REQUIREMENTS IN CA, IL OR FL. Q J w <br /> 8. 3'-0" MINIMUM ADA SPACE REQUIRED BETWEEN END OF PICK-UP SHELF AND FIRST KEYSTATION DIGITAL MENU BOARD BRACKET DETAIL BACK OF WALL VALANCE m o z Q <br /> 9. ORDER READY BOARD TO BE CENTERED ON PICK-UP SHELF OR ADA PLATFORM. NTS NTS Z � 2" U <br /> D U) <br /> Q <br /> THIS SLIP SHEET IS PROVIDED FOR REFERENCE ONLY. ADDITIONAL MODIFICATIONS TO THE HLZ, CENTER ISLAND AND POS SYSTEM WILL BE REQUIRED TO DIGITAL MENU BOARD (DMB) INSTALLATION NOTES: KEY NOTES Q o w o w <br /> COMPLETE THE DUAL POINT SERVICE INSTALLATION. PLEASE VERIFY LAYOUT, NUMBER OF KEYSTATIONS AND DIMENSIONS WITH KES AND REGIONAL DUAL POINT DMB SUPPORT EQUIPMENT INCLUDES: LL m Q o <br /> LEAD PRIOR TO FABRICATION OR INSTALLATION_ - NETWORK MANAGEMENT DEVICE (NMD) 1❑THIS SLIP SHEET IS PROVIDED FOR ELECTRICAL ROUGH-IN z LL. w o <br /> - 24 PORT ENHANCED WAYPORT SWITCH (LAWS) PREPARATION AND GENERAL DIGITAL MENU BOARD MOUNTING 0 - o o <br /> THIS EQUIPMENT IS TYPICALLY MOUNTED IN GUIDELINES. EVALUATE EXISTING VALANCE WALL STRUCTURE W 0 Q w <br /> DUAL POINT FRONT COUNTER PLANS TECHNOLOGY CLOSET OR IN MANAGER'S AND BACKING MATERIALS TO ENSURE ADEQUATE SUPPORT OF Z o <br /> EQUIPMENT. z o <br /> OFFICE. 0-) w <br /> 00 <br /> 9CA�E: N,T,g, DMB INSTALLERS TO ROUTE CONTROL WIRES FROM � F LLJ <br /> w o <br /> [Z]ALL HEADER AND WALL PENETRATIONS FOR CONDUITS CJ w - 1 <br /> NMD/LAWS ABOVE CEILING TO MENU BOARDOR OTHER ELECTRICAL ROUTING MUST BE SEALED TIGHT. _J ON W o w o <br /> VALANCE WALL. WIRES TO EXIT WALL VIA J-BOXES. <br /> • EACH DMB SECTION REQUIRES A DEDICATED MEDIA <br /> PLAYER. <br /> 0 <br /> z <br /> Li <br /> Li <br /> E490 <br /> U) ROUGH IN DETAILS <br />