My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008 RETROFIT
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
COMPLIANCE INFO_2008 RETROFIT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 11:26:32 AM
Creation date
12/13/2018 1:04:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 RETROFIT
RECORD_ID
PR0516526
PE
2361
FACILITY_ID
FA0012659
FACILITY_NAME
LOVE'S COUNTRY STORES OF CALIF #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
154
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' N <br /> S WRCB,January 2002 <br /> Page V2j Of <br /> 7• UNDER-DISPENSER CONTAINMENT C TESTING <br /> Test Method Developed By: ❑UDC Manufacturer ❑Industry Standard Professional Engineer <br /> i; <br /> ❑Other(Spec) f <br /> Test Method Used: ❑Pressure ❑Vacuum <br /> ydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used er,raEquipment Resolution: CP ��z t�`1 <br /> ►� <br /> UD <br /> u ItRAt <br /> ... ',.. <br /> vLC tt <br /> a-$ UDC#a3 S UDC#x s a UDC#d- S <br /> UDC Manufacturer. <br /> UDC Material: n V1 n <br /> o � <br /> UDC Depth: ?" ?f ft � <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: ' ' ,�i It t <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: ` J Xt <br /> Condition of UDC prior to <br /> testing: <br /> Portion of UDC Tested j ry ' l , <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both es ❑No ❑NA es ❑No ❑NA Yes <br /> product and water)? ❑No ❑NA es ❑No ❑NA <br /> Turbine shutdown response time iN d te, C! "0 <br /> Is system programmed for fail- Wu �' lug <br /> safe shutdown?* Yes ❑No ❑NA AYes, ❑No ❑NAes ❑No ❑NA es ❑No ❑NA <br /> Was fail-safe verified to be <br /> operational?* ❑Yes C*o ❑NA ❑Yes o ❑NA ❑Yes �*o ❑NA ❑Yes�o ❑NA <br /> Wait time betwee ying <br /> pressure/vacu waterd <br /> startinja test lv t-n rt,.-(A to r,-k%u vt �-es r^)t,�u� {S l p M-1 to V� Y <br /> Test Start Time: 8,qU 8: 3>" : 3 0 <br /> Initial Readin 2-,57 <br /> TestEnd Time: /D Y., <br /> Final Read ng(RF): <br /> Test Duration: 3 0 rA w <br /> Change in Reading(RF-RI): ti v <br /> Pass/Fail Threshold or Criteria: 16 vAF i 10"Pt a U,T,ijR, t kv 30 w l Prri e- rq 30 nV K- <br /> Test Result: Pass ❑Fail Pass ❑Fail Pass ❑Fail &es <br /> ss ❑Fail <br /> Was sensor removed for testing? es ❑No ❑NA es ❑No ❑NA es ❑No ❑NA ❑No ❑NA <br /> Was sensor properly replaced and <br /> verified functional after testing? Yes ❑No ❑NA X'es ❑No ❑NA AYes ❑No ❑NA W:,'�es ❑No ❑NA <br /> Comments-(include..information on repairs made prior to testing and recommended follow up for failed tests) <br /> ' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to M of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.