My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004 - 2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231464
>
COMPLIANCE INFO 2004 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2019 11:58:25 AM
Creation date
12/13/2018 3:43:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2012
RECORD_ID
PR0231464
PE
2361
FACILITY_ID
FA0000914
FACILITY_NAME
TIGER EXPRESS STORES
STREET_NUMBER
1399
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1399 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
456
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification <br />Site Address: <br />D. Results of Testing/Servicing <br />Software Version Installed: <br />Complete the following checklist: <br />Date of Testing/Servicing: <br />f -Yes <br />❑ No* <br />Is the audible alarm operational? <br />Yes <br />❑ No* <br />Is the visual alarm operational? <br />2r -Yes <br />❑ No* <br />Were all sensors visually inspected, functionally tested, and confirmedoperational? <br />9 -Yes <br />❑ No* <br />Were i l sensors installed at lowest point of secondary containment and positioned so that other equipment <br />will not interfere with their proper operation? <br />❑ Yes <br />❑ No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />gq-N/A <br />operational? <br />Yes <br />❑ No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />❑ N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors <br />initiate positive shut -down? (Check all that apply) [�Sump/Trench Sensors; R'Dispenser Containment <br />Sensors. 1 <br />Did von confirm positive shut -down due to leaks and sensor failure -/disconnection? P -Yes, ❑ No. <br />❑ Yes <br />e -No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />❑ N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating ro rf ? If so, at what percent of tank capacity does the alarm tri gerl ''"'";'n <br />❑ Yes* <br />5a'No <br />Was arr monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment <br />I <br />re laced and list the manufacturer name and model for all replacement parts in Section E, below. <br />❑ Yes* <br />2 -No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) j <br />❑ Product: ❑ Water. If ves, describe causes in Section E. below. <br />(-Yes <br />❑ No* <br />Was monitoring system set-areviewed to ensure proper settings? <br />19'Yes❑ <br />No* <br />Is all monitoring ment operational per manufacturer's cations'? I <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments: <br />
The URL can be used to link to this page
Your browser does not support the video tag.