SAW,J 0 A QU I N Environmental Health Department <br /> COUNTY <br /> F. SYSTEM PIPING CONTINUED: ® Q <br /> w <br /> Check Code t 00 = i <br /> Box Section '_ Uj <br /> HSC Piping compatible with material intended to be stored. Z <br /> Pq 25290.1 c 1 `°'� LLI <br /> 25290.2 c 1 <br /> v <br /> CL <br /> 23 CCR `� CD <br /> 2631(b) Design and construction of piping approved by independent testing organization (e.g. <br /> Piping, including vent lines, sloped toward tank(s)with minimum 1/8 inch slope per 1 T=run. IZ <br /> HSC <br /> 25290.1 k Vapor recovery,fill riser, and vent line piping are secondarily contained. <br /> �d 25290.2�c3&(j) <br /> G. OVERSPILL/ OVERFILL PREVENTION: <br /> Check Code <br /> Box Section <br /> 23 CCR Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br /> 2635(b) Manufacturer oPw Model 6571 EVRB-164042RT052 (just the bucket is P761C-FLDV) <br /> Approved overfill prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> ❑ Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> ❑ Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the <br /> 23 CCR restriction occurs when the tank is filled to no more than 95 percent capacity; and activate an <br /> 2635(b)(2) audible alarm at least five minutes before the tank overfills <br /> Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> ❑ Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling. <br /> Manufacturer OPW Model 71 SO-420C for 12'tanks and smaller <br /> Veeder Root VRI-790091-001 Overfill Alarm <br /> Veeder Root VR1-790095-001 Alarm Acknowledgement Switch <br /> H. CORROSION PROTECTION: <br /> Check Code <br /> Box Section <br /> I(] Fiberglass reinforced plastic(FRP) <br /> Piping corrosion protection: ❑ Steel with cathodic protection or impressed current <br /> ® 23 CCR ❑ Steel isolated from contact with backfill <br /> 2636(b) <br /> R FRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: ❑ Sacrificial Anode <br /> 91 23 CCR ❑ Steel tank with field installed cathodic protection or impressed <br /> 2635(a)(2) <br /> current <br /> 9 Tie-downs,when used, constructed of non-corrosive material or coated steel. <br /> 7 of 8 <br />