Laserfiche WebLink
SANJ O A Q U I N Environmental Health Department <br /> --COUNTY <br /> F. SYSTEM PIPING CONTINUED: <br /> Check Code <br /> Box Section <br /> HSC Piping compatible with material intended to be stored. <br /> 252901 <br /> 25290..2,%l <br /> 23 CCR <br /> 4r 2631(b) Design and construction of piping approved by independent testing organization(e.g. UL). <br /> Piping, including vent lines,sloped toward tank(s)with minimum 1/8 inch slope per 1 foot of run. <br /> 25290.1 k Vapor recovery,fill riser,and vent line piping are secondarily contained. J <br /> 25290.2�c�&Q) 2 < <br /> @ I i LJ <br /> * t p j <br /> G. OVERSPILL/ OVERFILL PREVENTION: allf- <br /> Check Rection F— CL <br /> Box Section "N o <br /> Lu <br /> O C? <br /> C 23 C bR Overspill containment having minimum capacity of 5 gallons provided at each tank fill loc CC <br /> Manufacturer OPUS Model 6571EVRB-164042RT052 Oust the bucket isP761C-FLDV Z <br /> Approved overfill prevention device provided at each tank fill location. <br /> Uj <br /> Choose One of the following methods: <br /> ❑ Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> C Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the <br /> 23 CCR restriction occurs when the tank is filled to no more than 95 percent capacity;and activate an <br /> 2635(bX2) audible alarm at least five minutes before the tank overfills <br /> _ Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> ❑ Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling. <br /> Manufacturer OPW Model 71 SO-420C <br /> Veeder Root VR1-790091-001 Overfill Alarm <br /> Veeder Root VR1-790095-001 Alarm Acknowledgement Switch <br /> H. CORROSION PROTECTION: <br /> Check Code <br /> Box Section <br /> Fiberglass reinforced plastic(FRP) <br /> Piping corrosion protection: .x Steel with cathodic protection or impressed current <br /> 23 CCR Steel isolated from contact with backfill <br /> fX 2636(b) <br /> XFRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: Sacrificial Anode <br /> 23 CCR ❑ Steel tank with field installed cathodic protection or impressed <br /> X 2635(a)(2) <br /> current <br /> -X Tie-downs,when used,constructed of non-corrosive material or coated steel. <br /> 17 n;: <br />