My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2420
>
2300 - Underground Storage Tank Program
>
PR0231580
>
COMPLIANCE INFO 2012 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2021 2:41:11 PM
Creation date
12/21/2018 3:49:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2017
RECORD_ID
PR0231580
PE
2361
FACILITY_ID
FA0003963
FACILITY_NAME
TRACY76
STREET_NUMBER
2420
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
Tracy
Zip
95377
APN
23802006
CURRENT_STATUS
01
SITE_LOCATION
2420 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
280
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TANK ANNULAR TESTING <br />Test Method By: • Manufacturer O Industry Standard O Professional Engr. O Other (see below) <br />Test Method Uses: O Pressure • vacuum o Hydrostatic o Other (see below) <br />Measuring Equipment Used: Vacuum Gauge (range 0 to 30 inches Hg) <br />uescription <br />TanK 91 <br />Tank #2 <br />Tank #3 <br />Product stored <br />Gasoline - 87 <br />Gasloine - 91 <br />Diesel <br />Tank manufacturer <br />Trustco <br />Trusco <br />Trusco <br />Tank material <br />Steel <br />Steel <br />Steel <br />Tank capacity (US gallons) <br />12,000 <br />6,000 <br />6,000 <br />Is this a multi -compartment tank? <br />No <br />No <br />No <br />Dry or Brine filled annular? <br />Dry <br />Dry <br />Dry <br />Monitoring system show normal annular? <br />Yes <br />Yes <br />Yes <br />Is water table above tank bottom? <br />Unknown <br />Unknown <br />Unknown <br />Was sensor removed for testing? <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Wait time for vacuum to stabilize (hrmin) <br />:15 <br />Test start time <br />1:48 PM <br />Initial vacuum (inches Hg) <br />7.0 <br />Test end time <br />2:48 PM <br />Final vacuum (inches Hg) <br />_ 6.0 <br />Test duration (hr:min) <br />1:00 <br />Change in vacuum (inches Hg) <br />1.0 <br />Pass/Fail threshold (inches Hg / hour) <br />2.0 <br />TEST RESULT <br />PASS <br />Comments: <br />0 2012 Walton Engineering, Inc. <br />