My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SAN JUAN
>
711
>
2200 - Hazardous Waste Program
>
PR0514022
>
COMPLIANCE INFO PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2019 11:07:30 AM
Creation date
12/27/2018 10:41:30 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514022
PE
2220
FACILITY_ID
FA0009754
FACILITY_NAME
MERRY X-RAY CHEMICAL CO INC
STREET_NUMBER
711
Direction
N
STREET_NAME
SAN JUAN
STREET_TYPE
AVE
City
STOCKTON
Zip
95203-1420
APN
13336035
CURRENT_STATUS
02
SITE_LOCATION
711 N SAN JUAN AVE
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.or /q ehd <br /> - — -- -- - --------- _._ <br /> I Cr)NTINI IATI0N FnRM -- 1 Payg; 5 of 5--..- <br /> rtcc:^:n9 1&JQ 1=r�T1AK1 Or-Dr►Q= Dat-F. 05/10/13 <br /> �_.��..,,.,.. �„. ,.�. ,.,t <br /> r-- ---- -- -- ---..-- - —__ _— —; <br /> r"" y Add;' <br /> SS: 711 N. San Juan Ave., Stockton <br /> I j <br /> S sAgAAA v OF i 11 i ATRO IS- <br /> � -�ta:;€99'::a�.s"s V. sss- v:i3:sr-a a:s.aN�: <br /> 703. An emergency coordinator and modified contingency plan information is lacking. There must be i <br /> at least one emergency coordinator on site or on call to coordinate emergency response measures, and <br /> the following information must be posted by a phone: the name and phone number of the emergency <br /> coordinator-, location of fire extinguishers, spill control equipment, and if present, fire alarm-, and the <br /> phone number of the fire department, unless the facility has a direct alarm. Immediately appoint an <br /> emergency coordinator and post the required information by a phone. A form is provided that can be <br /> used for this purpose. Submit proof of correction to the EHD by June 10, 2013. <br /> 812. Copies of universal waste disposal records were not found on site. A generator of universal waste <br /> (batteries, mercury containing equipment, lamps/bulbs, electronic devices, CRTs, CRT glass, aerosol <br /> cans) shall keep a record of each shipment of universal waste on site for at least three years. The <br /> record may take the form of a log, invoice, manifest, bill of lading, or other shipping document, and shall <br /> include the following: <br /> - Name & address of destination facility <br /> - Quantity & type of universal waste <br /> - Date of departure/shipment <br /> Begin this practice immediately. <br /> Complete and submit a copy of the Return to Compliance Certification to the EHD by June 10, 2013 <br /> along with a statement documenting the corrective actions that have been or will be taken for each <br /> violation and any supporting paperwork. <br /> Note: (corrected on site) <br /> The eyewash station was not functional at the time of inspection. All facility communications and alarm <br /> systems, fire protection equipment, spill control equipment, and decontamination equipment, shall be <br /> tested and maintained as necessary to assure its proper operation in time of emergency. Mr. Harrell <br /> turned the water on to the eyewash and tested it for proper operation at the time of inspection. <br /> This facility collects and accepts x-ray fixer waste from other facilities, sometimes on manifest, removes <br /> the silver from the waste, and packages the recycled fixer for reuse. The silver is sent out for disposal. <br /> Provided: Modified Contingency Plan template. Return to Compliance Certification forr <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: Received By: Title: <br /> Stacy Rivnr� ?Oql 468-344(: ` <br /> EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.