My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0006030
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1399
>
3500 - Local Oversight Program
>
PR0543988
>
ARCHIVED REPORTS XR0006030
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2018 10:59:28 AM
Creation date
12/28/2018 10:58:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0006030
RECORD_ID
PR0543988
PE
3500
FACILITY_ID
FA0000914
FACILITY_NAME
TIGER EXPRESS STORES
STREET_NUMBER
1399
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1399 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a'� r <br /> x L <br /> LA Irted Hydrogeolnoc Assessment workplan <br /> 13W E Yosernae Avenue Manteca Calrtornia <br /> SCOPE <br /> The proposed scope of work will be conducted according to the Aegis standard operating <br /> procedures included in Appendix A, and include the following <br /> • Drill, log, and sample two soil borings to approximately 35 feet below <br /> surface at the proposed locations shown on Figure 2 <br /> • Based on the results of field observations and/or measurements, submit <br /> selected soil samples to a state-certified laboratory for analysis <br /> • Complete the borings as 4-inch-diameter groundwater monitoring wells <br /> MW-3A and MW-6 <br /> • Measure stabilized water levels in each well Develop, purge, and collect <br /> water samples from each well for submittal to a state-certified laboratory for <br /> analysis <br /> • Complete a survey of the top-of-casing elevation of each well by a Incensed <br /> surveyor <br /> • Based on the water levels and survey data, determine the direction and <br /> gradient of groundwater flow beneath the site <br /> • Review the data and prepare a factual report of the investigation <br /> BACKGROUND <br /> Site Description <br /> The East Yosemite Avenue Moore Petroleum service station is located on the northwest <br /> corner of the intersection of Northwoods and East Yosemite Avenues in Manteca <br /> (Figure 2) The site is located in a commercial area of eastern Manteca Details of the <br /> site's current and former facilities, including previous and existing UST, were reported by <br /> Aegis in a "Problem Assessment Report, Including Quarterly Monitoring Report," dated <br /> November 12, 1991 <br /> Previous Investigation <br /> In August 1988, Earth Treatment Systems drilled four soil borings, SB-1 through SB-4, <br /> and completed one boring (SB-4) as a 2-inch-diameter monitoring well (MW-1) set <br /> approximately 36 5 feet below surface <br /> 90-098A WPN 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.