Laserfiche WebLink
Periodic Inspection Requirements <br /> "Uri l 'anks cf ,07� gallons nr less capagkr erre OATEGC'Rv ' TANKS. Ovcrers or CorVzult AS1s cf thi, s,e -re NOT <br /> requrcd to errlploy Courree OST Inspectors m inspect[tf er tanks to comply wi-h it estandard's reculrement;,but car be In <br /> comp lance with:the stanm,d by Inspecting the tanks themselves or having thelr employees Inspect to em.CenVaclt tarks <br /> larger thar 5000 ell rise•also sof-Insoecho.and only requ"re Inspection by in Cerrhele Inspector arts,20 years of ell _ <br /> What qualfficotlonsare required for the owner toself inspect his mnk,and how does the owneineed to know whorto inspect? <br /> Section 4 of the SP001 standard carries the qualifications of the Owner's Inspector as follows:"Period,2 Inspections are to be <br /> performed by an owner's lnspectoc The personnel performing these inspections 3 poll be knowledgeable o(storoge facihtyopera tic ns, <br /> the type ofAST an .its associated components,and characteristics of ml ligWd stored" <br /> Section 6 of the standard STI SP001 explains what is meant by the PERIODIC AST INSPECTION — and what needs to be _ <br /> inspected and kept In the owner's AST records.These are simple and straight forward tasks which can be performed by any <br /> competent owner or his employees.The staneard makes it very easy to know what to do and what to check for by providing <br /> a check list in the standard's Appendix C.The first section requires filling In Information about the owner and the ID ofthe <br /> tank,The second section Is the SP001 Monthly Inspection Checkllst which consists of 9 easy to check,Yes or No questions <br /> such as, is there water in primary or secondary containment,are there visible signs of leakage around the tank,corl - <br /> pad,or ground;are all tank openings properly sealed,e,c,The third section is the SP001 Annual Inspectign Checklistwhidl <br /> contains 27 questions with Yes or No answers and a space for comments. It should be noted that the Periodic Inspi. <br /> must be performed in addition to the Formal External Inspections <br /> Simply put,the periodic iispecdon requirements are visual,documented Inspections conducted by an owner's i nsoector,to <br /> assess the general AST co9ditions,as best as possible,withou°suspendrrg AST operations or removing the AST from service. <br /> ConVault strongly encourages theuse of the Monthly and Art Iospectlon Checklists provided In SPOo', and, ire fact, <br /> requlres some of these items he checked on a.weekly basis as part of the ConVault warranty. <br /> See Pages 10-12 fora Cortpuirspecific Maintenance Checkfisc <br /> ',. A copy of ConVault's weekly/monthly/yearly checklist is available online at <br /> litip://www.convault.com/pdfdoc/checklist,pdf. <br /> 888 965-322] <br />