My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1442
>
2300 - Underground Storage Tank Program
>
PR0518458
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/3/2020 10:28:22 AM
Creation date
1/18/2019 11:55:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0518458
PE
2361
FACILITY_ID
FA0013918
FACILITY_NAME
CHEVRON STATION #210997*
STREET_NUMBER
1442
STREET_NAME
COLONY
STREET_TYPE
Dr
City
RIPON
Zip
95366
APN
26102028
CURRENT_STATUS
01
SITE_LOCATION
1442 Colony Dr
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> —COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON STATION#210997` 1442 Colony Dr, RIPON January 17, 2019 <br /> File Review <br /> 123 CCR 2637.1(d), Failure to submit the"Spill Container Testing Report Form"within 30 days after the test V R n COS <br /> 2637.1(a) <br /> 124 CCR 2637.2(d&e), "Overfill Prevention Equipment Inspection Report Form"not submitted within 30 days of inspection ■V u R ii COS <br /> 2665(a&b) <br /> On Site Records <br /> 201 CCR 2712(b) Failure to maintain monitoring,maintenance,and follow up action records V ❑R ❑COS <br /> 202 CCR 2715(c)(3), Failure to maintain the"Facility Employee Training Certificate"on-site(after October 1,2018) =V ❑R o COS <br /> 2715(c)(4) <br /> 203 CCR 2712(b) Failure to maintain records of repairs,lining,and upgrades on site,for the life of the UST ■V ■R ■COS <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site o V ❑R ❑COS <br /> 205 CCR 2712(i),2634(e) Failure to submit a current UST Response Plan and have it available onsite ❑V ❑R ❑COS <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions ■V o R ❑COS <br /> 207 HSC 25294 Failed to record unauthorized release from primary containment n V o R ❑COS <br /> 208 CCR 2650(e),2652 Failed to notify the EHD of a reportable unauthorized release and/or prepare a report o V ❑R ❑COS <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days o V o R n COS <br /> 210 CCR 2716(f) DO monthly reports not maintained on site for 12 months or for 36 months(after October 1,2018) o V o R o COS <br /> 211 CCR 2715(c)(2) No employee present that were trained in the operation and maintenance of the UST system by a DO o V o R o COS <br /> 212 CCR 2715(f)(2) Unstaffed facility failed to have or implement a training program approved by the EHD n V n R ❑COS <br /> 213 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept ❑V ❑R ❑COS <br /> 214 HSC 25281.5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept o V o R ❑COS <br /> 215 CCR 2712(1) Failure to retain a copy of the permit to operate at the facility ❑V ❑R ❑COS <br /> UST System Observations <br /> 301 HSC 25292.1(a) UST system is not operated to prevent unauthorized release,including spills and overfills ❑V ❑R ❑COS <br /> 302 HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003) ❑V o R ❑COS <br /> 303 HSC 25290.2(d) Monitoring system not maintained to detect entry into secondary containment(Jul 2003-Jun 2004) ❑V ❑R ❑COS <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004) ❑V n R o COS <br /> 305 HSC 25290.1(e) VPH monitoring of the interstitial spaces of the UST system is not maintained o V o R ❑COS <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity o V o R ❑COS <br /> 307 CCR 2631(g),2632(c) Monitoring system of the interstitial space of a double walled system not maintained o V o R o COS <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm ❑V ❑R ❑COS <br /> 309 CCR 2636(f)(1) Monitoring in sump/UDC failed to activate an audible and visual alarm or stop the flow product ❑V ❑R ❑COS <br /> 310 CCR 2636(f)(4) Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs o V o R o COS <br /> 311 CCR 2638(a),26410) Failed to properly program,calibrate,operate,or maintain leak detection equipment u V o R ❑COS <br /> 312 CCR 2638(f),2641(i) Failed to affix a tag sticker on monitoring equipment certified,repaired,or replaced ❑V ❑R ❑COS <br /> 313 HSC 25290.1,25290.2, Failure to construct,operate,and maintain primary containment as product-tight o V o R o COS <br /> 25291 <br /> FA0013918 PRO518458 SCO01 01/17/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 2 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.