My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1442
>
2300 - Underground Storage Tank Program
>
PR0518458
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/3/2020 10:28:22 AM
Creation date
1/18/2019 11:55:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0518458
PE
2361
FACILITY_ID
FA0013918
FACILITY_NAME
CHEVRON STATION #210997*
STREET_NUMBER
1442
STREET_NAME
COLONY
STREET_TYPE
Dr
City
RIPON
Zip
95366
APN
26102028
CURRENT_STATUS
01
SITE_LOCATION
1442 Colony Dr
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON STATION#210997` 1442 Colony Dr, RIPON January 17, 2019 <br /> UST System Observations <br /> 314 HSC 25290.1,25290.2, Failed to have secondary containment or secondary containment not tight COS <br /> 25291 <br /> 315 HSC 25291(e) Water in secondary containment not removed,analyzed,and property disposed of(pre-Jul 2003) o V c R o COS <br /> 316 HSC 25290.1(c3), Secondary containment not constructed to prevent water intrusion(after Jul 2003) ❑V o R o COS <br /> 25290.2(c3) <br /> 317 CCR 2636,2643(c)(1), Line leak detector(LLD)not installed o V o R o COS <br /> 2666(f) <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch o V o R o COS <br /> 319 CCR 2635,2637.1, No spill bucket,failed to contain 5 gallons,no means to keep it empty,or failed to be tested o V o R o COS <br /> 2665,2712 <br /> 320 CCR 2635,2637.2, Failure to comply with the installation,inspection,or record keeping of the overfill prevention ■V o R o COS <br /> 2665,2712 <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden o V o R o COS <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status o V o R o COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status o V o R o COS <br /> 324 CCR 2717.1(g) Tampered with red tag o V o R o COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST o V o R o COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V o R o COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored o V o R o COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements o V o R o COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements o V o R o COS <br /> 330 CCR 2636(f),2666(c), No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm o V o R o COS <br /> 2666(f) <br /> 331 CCR 2630(d),2641(a) Liquid does not flow into the sump in the event of a leak(i.e.,failure to remove test boot). o V in R o COS <br /> 332 CCR 2631(b&d), Primary and/or secondary containment not constructed in accordance with the established standards o V o R o COS <br /> 2666(b&e) <br /> 333 CCR 2635,2636(b), Failure to comply with the cathodic protection system requirements o V o R o COS <br /> 2662,2712 <br /> 334 CCR 2666(b)(2) Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair in V o R o COS <br /> 335 CCR 2630,2632,2643, Equipment or methods used to monitor the UST system are not certified by an independent third-parry ❑V o R o COS <br /> 2644.1 <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3), Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 2641(b) <br /> 402 CCR 2643(d) No monitoring or record maintenance for single-walled conventional suction systems(pre-Jan 1984). o V c R ❑COS <br /> 403 CCR 2643(d),2661(f) Failure to conduct 0.1 gph test for single-walled conventional suction systems(pre-Jan 1984) o V o R o COS <br /> 404 CCR 2643(e),2661(f) Biennial 0.1 gph line integrity test for single-walled gravity piping not performed(pre-Jan 1984) o V o R o COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V o R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> FA0013918 PRO518458 SCO01 01/17/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 3 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.