Laserfiche WebLink
S A N J O A Environmental Health Department <br /> QUIN <br /> ' I I q <br /> - COUNTY <br /> - <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : Date : <br /> QUICK SHOP 2072 W YOSEMITE AVE , MANTECA TDecember 18 , 2018 <br /> SUMMARY OF VIOLATIONS <br /> ( CLASS I , CLASS II , or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 123 CCR 2637 . 1 ( d ) , 2637 . 1 (e ) Failure to submit the " Spill Container Testing Report Form " within 30 days after the test . <br /> Spill container testing was performed on 9/ 19/ 17 and a test report was submitted on 3/23/ 18 , 6 months late . A copy <br /> of the test report must be submitted within 30 days of the tests . Take all necessary precautions to ensure testing <br /> and submittal of test reports are performed in a timely manner. <br /> The operator provided a statement to close this violations while the inspector was on site . <br /> This was corrected on site . <br /> This is a repeat violation , Class ll . <br /> 201 CCR 2712 ( b ) Failure to maintain monitoring , maintenance , and follow up action records . <br /> Maintenance and monitoring records for the last three years were not found on site . An alarm for L- 13 UDC 7/8 <br /> occurred on 5/4/ 18 , however no records on how this alarm was responded to were found on site . These records <br /> shall be maintained on site for at least three years . Monitoring records include : ( 1 ) date and time of all monitoring or <br /> sampling ; (2 ) monitoring equipment calibration and maintenance records ; (3 ) results of any visual observations ; (4 ) <br /> results of sample analysis performed a lab or in the field ; ( 5 ) logs of all readings of gauges or other monitoring <br /> equipment , ground water elevations , or other test results ; (6 ) results of inventory readings and reconciliations . <br /> Immediately locate and maintain all maintenance and monitoring records for the last three years on site and submit <br /> copies to the EHD . <br /> The operator provided a statement to close this violations while the inspector was on site . <br /> This was corrected on site . <br /> This is a repeat violation , Class II , <br /> 210 CCR 2716 ( f) DO monthly reports not maintained on site for 12 months or for 36 months ( after October 1 , 2018 ) . <br /> The June 2018 , August 2018 and September 2018 designated operator monthly inspection reports were not found <br /> on site . Designated operator monthly inspection reports for the previous twelve months shall be retained on site . <br /> Locate and ensure that copies of the previous twelve months of designated operator monthly inspection reports are <br /> maintained on site . Submit copies to the EHD . <br /> The operator provided a statement to close this violations while the inspector was on site . <br /> This was corrected on site . <br /> This is a repeat violation , Class II . <br /> FA0004625 PR0231426 SC333 12/18/2018 <br /> EHD 23-01 Rev. 09/28/2018 Page 7 of 9 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 468 - 3420 F 209 464 -0138 1 www . sjcehd . com <br />