My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2072
>
2300 - Underground Storage Tank Program
>
PR0231426
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/17/2023 3:27:12 PM
Creation date
1/18/2019 11:57:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231426
PE
2361
FACILITY_ID
FA0004625
FACILITY_NAME
NATIONAL PETROLEUM MANTECA
STREET_NUMBER
2072
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
22202001
CURRENT_STATUS
01
SITE_LOCATION
2072 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
132
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 , , i Environmental Health Department <br /> SAN JOAQUIN <br /> i , , , 7; <br /> C (D U \1 I Y Ze I ( 1611q <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : Date : <br /> QUICK SHOP 2072 W YOSEMITE AVE , MANTECA December 18 , 2018 <br /> SUMMARY OF VIOLATIONS <br /> ( CLASS I , CLASS II , or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 315 HSC 25291 (e ) Water in secondary containment not removed , analyzed , and properly disposed of ( pre-Jul 2003 ) . <br /> Liquid was observed in the UDC 5/6 sump . If water could enter into the secondary containment by precipitation or <br /> infiltration , it must be removed and disposed of properly . The service technician removed 5 cups of liquid from UDC <br /> 5/6 sump . Ensure that all sumps and annular spaces are maintained free of liquid . <br /> This was corrected while inspector was on site . <br /> This is a repeat violation , Class II . <br /> 319 CCR 26351 2637 . 1 , 2665 , 2712 No spill bucket, failed to contain 5 gallons , no means to keep it empty, or failed to be <br /> tested . <br /> The Diesel direct-bury spill container failed when tested . All spill containers shall have a minimum capacity of five <br /> gallons and be capable of containing a spill or overfill until it is detected or cleaned up . Immediately discontinue <br /> deposition of petroleum into this tank until the component is repaired or replaced by a properly licensed , trained , and <br /> certified contractor under permit and inspection of the EHD . The Diesel spill container had red tag #4210 affixed <br /> prior to the inspection , because this spill container is direct buried , the red tag will remain on the Diesel tank until <br /> repairs are completed . <br /> This is a repeat violation , Class II . <br /> 320 CCR 26351 2637 . 2 , 26651 2712 Failure to comply with the installation , inspection , or record keeping of the overfill <br /> prevention . <br /> The Mechanical overfill prevention system used as the overfill prevention system is not currently functional on the <br /> 100 octane , 110 octane , 87 ( 1 ) product , 87 (2 ) product , and 91 product UST system because it is set above 95 % . <br /> Immediately repaired or replaced by a properly licensed , trained , and certified contractor under permit and <br /> inspection of the EHD . If the failed component can ' t be replaced immediately, there is a possibility that the 100 <br /> octane , 110 octane , 87 ( 1 ) product, 87 (2 ) product, and 91 product UST system may be red tagged to prevent fuel <br /> inputs . The operator, Pete Chahoud , is aware of the failures and provided a statement to the inspector stating that <br /> he would repair and retest with passing results by 1 / 18/ 19 or he would be red tagged . <br /> This is a Class II violation. <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements . <br /> This UST system was found to be illegally abandoned . No person shall abandon an UST system without complying <br /> with the requirements of HSC 25298 . Immediately obtain a permit from the EHD to remove this UST system . A <br /> " Failure to Obtain a Permit" penalty applies . <br /> The operator provided a statement to close this violations while the inspector was on site . <br /> This was corrected on site . <br /> This is a repeat violation , Class ll . <br /> Overall Inspection Comments : <br /> An inspection report was provided to the facility operator on the day of inspection . The report was amended by <br /> FA0004625 PR0231426 SC333 12/18/2018 <br /> EHD 23-01 Rev, 09/28/2018 Page 8 of 9 Underground Storage Tank Program CIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 468 - 3420 F 209 464 -0138 1 www . sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.