Laserfiche WebLink
SAN JOAQUIN b <br /> AMENDED��� Environmental Health Department <br /> � ��_! <br /> ---COUNTY- --- - <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> QUICK SHOP 2072 W YOSEMITE AVE, MANTECA December 18, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 111 CCR 2638(a) & (b), 2641 Q) Failed to test monitoring and leak detection equipment annually. <br /> 1)Annual monitoring system certification and leak detector testing were last performed on 9/19/17 and was <br /> completed on 12/18/18, 3 months past due. These tests are required once every 12 months. Take all necessary <br /> precautions to ensure testing is performed in a timely manner. <br /> The operator provided a statement to close this part of the violation while the inspector was on site. <br /> 2) When the inspector arrived on site, the service technician had indicated that he conducted the leak detector test <br /> for the 100 octane and 110 octane product tank. When the inspector asked how the test was conducted since the <br /> amount of fuel in both tanks was low, the service technician (Felix Ramirez) stated the the automatic tank gauge <br /> was removed from the tank to move the float to a higher level in order to"override"the system to allow the turbine <br /> run. The service technician ran the leak detector test for the 100 octane and 110 octane product tanks with the <br /> automatic tank gauge outside the tanks and not in operating conditions. Based on code section 2638(a) "All <br /> monitoring equipment used to satisfy the requirements of this article shall be installed, <br /> calibrated, operated and maintained in accordance with manufacturer's instructions, and certified every 12 months <br /> for operability, proper operating condition, and proper calibration". Ensure to perform leak detection test on 100 <br /> octane and 110 octane schedule this test, providing a 48 hour notice to EHD while the 100 octane and 110 octane <br /> tanks are in operating condition upon fuel delivery within 30 days from receiving this amended report. <br /> This is a repeat violation, Class II. <br /> 113 CCR 2638(c), 2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the <br /> test. <br /> Annual monitoring system certification, leak detector testing, and spill container testing was performed on 9/19/17 <br /> and a test report was submitted on 3/23/18 , 6 months late. A copy of the test report must be submitted within 30 <br /> days of the tests. Take all necessary precautions to ensure testing and submittal of test reports are performed in a <br /> timely manner. <br /> The operator provided a statement to close this violations while the inspector was on site. <br /> This was corrected on site. <br /> This is a repeat violation, Class Il. <br /> FA0004625 PR0231426 SC333 12/18/2018 <br /> EHD 23-01 Rev.09/28/2018 Page 5 of 9 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 wvvw.sjcehd.com <br />