Laserfiche WebLink
!L as 31 Environmental Health Department <br /> SAN JOAQUIN ,z$ bi; <br /> ---C 0 U N ..r Y-- - <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> QUICK SHOP 2072 W YOSEMITE AVE, MANTECA December 18, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 10/19/18 and an inspection report was issued identifying information to be submitted <br /> to bring this site into compliance. This information was required to be submitted by 11/18/18 . This information has <br /> not been received resulting in a non-compliant status for this facility. An operator that receives an inspection report <br /> shall have 30 days to submit a written response that includes a statement documenting corrective actions taken or <br /> proposing corrective actions which will be taken. Ensure that a written response documenting corrective actions <br /> taken or proposed is submitted within 30 days of receiving an inspection report. <br /> October 19, 2018 inspection <br /> -Failure to submit and maintain complete and current financial responsibility documents. <br /> -Failed to submit"Secondary Containment Testing Report Form"within 30 days after the <br /> test. <br /> - Failure to submit"Monitoring System Certification Form"within 30 days of completion of the test. <br /> -Failed to submit a written response within 30 days of receiving an inspection report. <br /> - Failure to submit the"Spill Container Testing Report Form"within 30 days after the test <br /> -Failure to maintain monitoring, maintenance, and follow up action records. <br /> -DO monthly reports not maintained on site for 12 months or for 36 months (after October 1, 2018). <br /> -Failed to comply with all permanent closure requirements. <br /> September 19, 2017 inspection <br /> -No permit to operate. <br /> -UST system incapable of detecting leak from primary into secondary containment(pre-Jul,2003). <br /> June 10, 2016 <br /> - Failed to comply with temporary closure requirements. <br /> -Failed to comply with temporary closure requirements. <br /> March 22, 2016 inspection <br /> - Failed to comply with temporary closure requirements <br /> The operator provided a statement to close this violations while the inspector was on site. <br /> This was corrected on site"' <br /> This is a repeat violation, Class II. <br /> FA0004625 PR0231426 SC333 12/18/2018 <br /> EHD 23-01 Rev.09/28/2018 Page 6 of 9 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />