My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FIELD DOCUMENTS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
B
>
1603
>
3500 - Local Oversight Program
>
PR0543430
>
FIELD DOCUMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2019 9:53:40 AM
Creation date
2/5/2019 9:32:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
FIELD DOCUMENTS
RECORD_ID
PR0543430
PE
3528
FACILITY_ID
FA0009377
FACILITY_NAME
CAL TRANS MAINT SHOP 10
STREET_NUMBER
1603
Direction
S
STREET_NAME
B
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16918002
CURRENT_STATUS
02
SITE_LOCATION
1603 S B ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The TPHg was selected based on experience at other sites,benzene'was based on the U. S. <br /> Environmental Protection Agency (EPA) Region IX's industrial PRG and for groundwater the <br /> regulatory limits established for drinking water. j <br /> a <br /> } These goals are considered conservative in that the risk asse Isment'calculated the risk for all <br /> exposure pathways to be below the EPA acceptable criteria for both carcinogenic and <br /> noncarcinogenic chemicals (URS, 1999). These goals may not be achievable due to site <br /> conditions and will be revisited as remediation progresses. <br /> P <br /> 3.3 Selected Remedial Alternative l <br /> The 1996 pilot test (Geocon, 1996) applied a vacuum of 12,500 pascals (Pa) (50 inches of water <br /> [in. WC]) to well VW-1 and resulted in a flow rate from VW-1 of 102 standard cubic meters per <br /> hour (sm3/hr) (60 standard cubic ft per minute [scfm]). An influence of up to 719 Pa(2.85 in. <br /> WC) was observed in well VM-1 located 6.1 m(20 ft) away An influence of up to 650 Pa(2.6 <br /> in. WC) was observed in well VM-2, located 12.2 m(40 ft) away. Based on these <br /> measurements, a radius of influence (ROI) of 24.4 m (80 ft)�was postulated. The SVE wells will <br /> be located to influence the soil containing petroleum hydroa bons'and benzene and to capture <br /> the injected air from air sparging. Figure 7 shows the proposed locations of the vapor extraction <br /> r-� wells (VEW-I and VEW-2). Each well will be screened froin 4.6 in (15 ft) to 14 m (46 ft) bgs to <br /> encompass the soil containing petroleum hydrocarbons. The <br /> well 'screens will end above the <br /> water table to prevent groundwater being drawn into the well and covering the well screen. <br /> Based on IT's experience, the typical ROI for an air sparge well is,7.6 m (25 ft) based on <br /> experience. Therefore, four air sparge wells (ASW-1 through ASW-4) are proposed and shown <br /> on Figure 7. <br /> '1 .9 <br /> I1. <br /> f <br /> 'f <br /> S cOP•Nl acDIIIM21PAJIVJIIM1329942sb.das 3-2 <br /> (0102 ) f <br />