My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
B
>
1603
>
3500 - Local Oversight Program
>
PR0543430
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2019 11:08:01 AM
Creation date
2/5/2019 9:38:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
WORK PLANS
RECORD_ID
PR0543430
PE
3528
FACILITY_ID
FA0009377
FACILITY_NAME
CAL TRANS MAINT SHOP 10
STREET_NUMBER
1603
Direction
S
STREET_NAME
B
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16918002
CURRENT_STATUS
02
SITE_LOCATION
1603 S B ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
219
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. Use sorbent pads to collect product and impede its flow, if possible. <br /> 7. Call Fire Department immediately if a fire or an emergency develops. <br /> 8. Inform STANTEC Project Manager about the situation. <br /> 9. Determine if the client wants STANTEC to repair the damage or if the client will use an emergency repair contractor. <br /> 10. Based on agreements, contact emergency spill contractor for containment of free product. The contact for this project will be IWM <br /> Phone: 408 433-1990 <br /> 11. Advise the client of spill discharge notification requirements and determine who will complete and submit forms. (Do not submit or <br /> report to agencies without the client's consent.) Document each interaction with the client and regulators and note, in writing; name, <br /> title, authorizations, refusals, decisions, and commitments to any action. <br /> 12. Do not transport or approve transportation of contaminated soils or product until proper manifests have been completed and approved. <br /> Be aware that soils/ product may meet criteria for hazardous waste. <br /> 13. Do not sign manifests as generator of wastes; contact PM or Waste Compliance Manager to discuss waste transportation. <br /> Notifications — a spilllrelease requires completion of an Incident Investigation (II). The incident shall be reported immediately after <br /> stabilizing the victim(s)lsite. The PM must involve the clientlgenerator in the Incident Investigation process. The client/generator <br /> is under obligation to report to the proper government agencies. If the spill extends into waterways, the Coast Guard and the <br /> National Response Center (800) 424-8802 must be notified immediately by the client or by STANTEC PM with the client's <br /> permission. <br /> All spills/releases must be reported per site%lient requirements per procedures listed in Attachment 1. <br /> All spills/releases must be reported to Terrence Fox Phone: 559) 243-8397 at CALTRANS District 6. <br /> Emergency Decontamination Procedures 4 <br /> Ensure eyewash bottle, water(unless the chemicals of concern are water reactive), and other decontamination aids are available on-site. <br /> In the event of eme[gency emergencydecontamination: .__.._._ . <br /> • Secure area or movelevacuate to the emergency gathering location. r <br /> Immediately.:remove any-contaminated-PPE_or.-clothing-(gloves;etc) <br /> • If possible, wash contaminated area with mild soap and water. Use eyewash station if necessary. <br /> • Observe the contaminated area. <br /> • Repeat washing as necessary. <br /> Notify SHSO immediately. <br /> Exposure to contaminated individuals should be limited to personnel wearing the proper PPE to avoid unnecessary exposure. <br /> STANTEC Consulting Corporation <br /> 4-4 <br />